Schneider Electric LADN403G — Motor Control Accessories

LADN403G TeSys Deca Auxiliary Contact Block, 4NO, Spring Ter

MPNLADN403G
Obsolete

Schneider Electric TeSys Deca auxiliary contact block, LADN403G, 4NO, front mounting, spring terminals, EN 50012.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LADN403G — Identification
ParameterValue
Product / component typeAuxiliary contact block
Product rangeTeSys TeSys Deca
LADN403G — Electrical
ParameterValue
Rated operational voltage (Ue)690 V AC 25...400 Hz
Pole / contact composition4 NO
LADN403G — Cable & Connector
ParameterValue
Terminal connection capacitySpring terminals 2 cable(s) 2.5 mm²flexible without cable end Spring terminals 2 cable(s) 2.5 mm²rigid
LADN403G — Mechanical
ParameterValue
Width44 mm
Height48 mm
Depth42 mm
ColourDark grey
LADN403G — Environmental
ParameterValue
IP protection ratingIP20 conforming to IEC 60529
Operating ambient temperature-5...60 °C
Storage ambient temperature-60...80 °C
Operating altitude3000 m
Environmental classNormal environment
LADN403G — Approvals
ParameterValue
Conformance standardsEN/IEC 60947-5-1 GB/T 14048.5 EN 50012 UL 60947-5-1 CSA C22.2 No 60947-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ

Product details

The LADN403G is a front-mounted auxiliary contact block in the TeSys Deca range, providing 4 normally-open instantaneous contacts via spring-cage terminals. It is designed to snap onto the front of a TeSys Deca contactor or reversing starter, adding status feedback or interlocking logic without additional wiring space on the DIN rail. Rated operational current is 6 A at 120 V AC-15 (pilot-duty inductive loads) and 0.55 A at 125 V DC-13 (solenoid/brake loads).

The 4NO contact configuration gives four independent normally-open auxiliary circuits — enough to cover a contactor's feedback to a PLC, a status lamp, and a seal-in circuit without paralleling contacts. The spring terminals accept two 2.5 mm² flexible or rigid conductors each, so field wiring is tool-less and vibration-resistant. Minimum switching capability is 5 mA at 17 V, meaning the block can reliably switch low-level PLC inputs or electronic loads without contact wetting issues. Rated making capacity is 140 A AC and 250 A DC per IEC 60947-5-1, so the block can handle inrush from multiple contactor coils or small solenoids. Short-time withstand ratings (100 A for 1 s, 140 A for 100 ms) support coordination with upstream 10 A GG fuses.

Compliant with EN/IEC 60947-5-1, GB/T 14048.5, EN 50012, UL 60947-5-1, and CSA C22.2 No 60947-5-1. Also meets glow-wire requirements of IEC 60335-1 Clause 30.2 and Annex JJ of IEC 60335-2-40 / UL 60335-2-40 for HVAC equipment. IP20 finger-safe protection per IEC 60529.

Frequently asked questions

What are the key electrical ratings of LADN403G?

Rated operational current is 6 A at 120 V AC-15 and 0.55 A at 125 V DC-13. Conventional free-air thermal current is 10 A at 60 °C. Insulation voltage is 690 V AC. Minimum switching is 5 mA at 17 V.

What standards does LADN403G comply with?

It complies with EN/IEC 60947-5-1, GB/T 14048.5, EN 50012, UL 60947-5-1, CSA C22.2 No 60947-5-1, and the glow-wire requirements of IEC 60335-1 Clause 30.2 and IEC/UL 60335-2-40 Annex JJ.

MPN
LADN403G