Skip to main content
Schneider Electric LADT09

Schneider LADT09 TeSys Deca Time Delay Block, 0.3-3s, Obsole

MPN LADT09
Obsolete

Schneider Electric TeSys Deca LADT09, time delay auxiliary contact block, 1NO + 1NC, on delay 0.3-3s, front mount, Faston terminals.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LADT09 specifications
ParameterValue
Timer typeOn delay
Protection typeGG fuse 10 A
Voltage690 V AC 25...400 Hz
Insulation voltage ui690 V conforming to IEC 60947-5-1 600 V conforming to UL 60947-5-1 600 V conforming to CSA C22.2 No 60947-5-1
Current6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13
IP ratingIP20
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max70 °C
Temp operating min-40 °C
Storage temperature-60...80 °C
ColorDark grey
Depth61 mm
Width44 mm
Height48 mm
Mechanical life cycles5 Mcycles
Time delay range0.3–3 s
Operating temperature-40...70 °C

Product details

The LADT09 is a time delay auxiliary contact block from the TeSys Deca range, designed to bolt onto the front of a contactor or starter to add a programmable on-delay to the auxiliary circuit. It switches 1 NO + 1 NC contacts with a time delay range of 0.3...3 s, set by a front-mounted dial. The contacts are rated for 6 A at 120 V AC-15 (pilot duty) and 0.55 A at 125 V DC-13 (solenoid/brake loads), with a conventional free air thermal current of 10 A at 60 °C. The block uses Faston terminals for quick wiring, mounts in the front accessory slot of TeSys Deca contactors, and carries IP20 finger-safe protection per IEC 60529. It complies with EN/IEC 60947-5-1, UL 60947-5-1, and CSA C22.2 No 60947-5-1, making it acceptable for North American and European control panels.

The 0.3...3 s on-delay covers common timing needs like star-delta transition, conveyor start sequencing, or fan-coil delay. The 1 NO + 1 NC contact set gives you one make and one break — enough for a single timing function without extra interposing relays. The AC-15 rating (6 A at 120 V) is what governs pilot duty for contactor coils and indicator lamps; the DC-13 rating (0.55 A at 125 V) is the one to watch if you are switching DC solenoid valves or brake coils — the DC current is much lower than the AC figure because DC arcs are harder to extinguish. Minimum switching capability is 5 mA at 17 V, so it will handle PLC-level dry contacts without trouble.

MPN
LADT09