Schneider Electric TeSys Deca LADT09, time delay auxiliary contact block, 1NO + 1NC, on delay 0.3-3s, front mount, Faston terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LADT09 — Identification
ParameterValue
Product / component typeTime delay auxiliary contact block
Product rangeTeSys TeSys Deca
LADT09 — Electrical
ParameterValue
Rated operational voltage (Ue)690 V AC 25...400 Hz
Pole / contact composition1 NO + 1 NC
LADT09 — Cable & Connector
ParameterValue
Terminal connection capacityFaston terminals
LADT09 — Mechanical
ParameterValue
Width44 mm
Height48 mm
Depth61 mm
ColourDark grey
LADT09 — Environmental
ParameterValue
IP protection ratingIP20 conforming to IEC 60529
Operating ambient temperature-40...70 °C
Storage ambient temperature-60...80 °C
Operating altitude3000 m
Environmental classNormal environment
LADT09 — Approvals
ParameterValue
Conformance standardsEN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN 50012 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ

Product details

The LADT09 is a time delay auxiliary contact block from the TeSys Deca range, designed to bolt onto the front of a contactor or starter to add a programmable on-delay to the auxiliary circuit. It switches 1 NO + 1 NC contacts with a time delay range of 0.3...3 s, set by a front-mounted dial. The contacts are rated for 6 A at 120 V AC-15 (pilot duty) and 0.55 A at 125 V DC-13 (solenoid/brake loads), with a conventional free air thermal current of 10 A at 60 °C. The block uses Faston terminals for quick wiring, mounts in the front accessory slot of TeSys Deca contactors, and carries IP20 finger-safe protection per IEC 60529. It complies with EN/IEC 60947-5-1, UL 60947-5-1, and CSA C22.2 No 60947-5-1, making it acceptable for North American and European control panels.

The 0.3...3 s on-delay covers common timing needs like star-delta transition, conveyor start sequencing, or fan-coil delay. The 1 NO + 1 NC contact set gives you one make and one break — enough for a single timing function without extra interposing relays. The AC-15 rating (6 A at 120 V) is what governs pilot duty for contactor coils and indicator lamps; the DC-13 rating (0.55 A at 125 V) is the one to watch if you are switching DC solenoid valves or brake coils — the DC current is much lower than the AC figure because DC arcs are harder to extinguish. Minimum switching capability is 5 mA at 17 V, so it will handle PLC-level dry contacts without trouble.

Frequently asked questions

What replaces the LADT09?

There is no direct official successor order code from Schneider. The TeSys Deca range has been superseded by the TeSys D series; a functional equivalent is the LADT0 on-delay block, but you must verify mounting and wiring compatibility with your existing contactor base.

What are the key ratings of the LADT09?

On-delay 0.3-3 s, 1 NO + 1 NC contacts, rated operational current 6 A at 120 V AC-15 and 0.55 A at 125 V DC-13, conventional free air thermal current 10 A at 60 °C, insulation voltage 690 V, IP20 protection.

What standards does the LADT09 comply with?

It complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, and GB/T 14048.5, making it suitable for global control panel applications.