Skip to main content
Schneider Electric LC1F1000FD — Contactors

Schneider TeSys F LC1F1000FD Contactor, 1250 A AC-3, EOL

MPNLC1F1000FD
Obsolete

Schneider Electric TeSys F LC1F1000FD, 3-pole contactor, 1250 A AC-3 rated operational current, 110 V DC coil, plate mount, end-of-life status.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F1000FD — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load Motor control
LC1F1000FD — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 440 V AC 50/60 Hz
Utilisation categoryAC-1 AC-3
LC1F1000FD — Contacts & Poles
ParameterValue
Pole configuration3P
LC1F1000FD — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH
LC1F1000FD — Approvals
ParameterValue
StandardsEN 60947-4-1 IEC 60947-1 EN 60947-1 IEC 60947-4-1
LC1F1000FD — Mechanical
ParameterValue
Width438 mm
Height332 mm
Depth238.6 mm

Product details

The Schneider Electric TeSys F LC1F1000FD is a 3-pole direct on-line contactor rated for heavy motor control and resistive loads. It carries a rated operational current of 1250 A in AC-3 duty (motor switching) at <= 440 V AC, and a conventional free air thermal current of 1250 A at 40 °C. The coil is 110 V DC standard. Rated breaking capacity is 8 kA per IEC 60947-4-1, and the short-time withstand current is 10 kA for 10 seconds at 40 °C — enough to coordinate with upstream 1400 A gG fuses at <= 440 V. The contactor is designed for plate mounting, not DIN rail, so factor in panel layout accordingly.

Motor power and duty cycle

This contactor handles 315 kW at 220–230 V three-phase, 560 kW at 380–400 V, 630 kW at 415 V, and 670 kW at 440 V. That puts it squarely in the large-motor class — think big pumps, compressors, or conveyor drives on 400 V class systems. Maximum operating rate is 600 cycles per hour at 55 °C.

Lifecycle reality — end of life

This part carries an end-of-life (EOL) status. Schneider has discontinued the LC1F1000FD. Sourcing is through last-time-buy or surplus channels.

The LC1F1000FD is designed and certified to EN 60947-4-1 and IEC 60947-4-1 (the contactor standard), plus EN/IEC 60947-1 (general rules). Rated insulation voltage is 1000 V per IEC 60947-4-1, with an impulse withstand voltage of 8 kV. Overvoltage category III. The front face with shrouds provides IP20 protection per IEC 60529 and VDE 0106.

Frequently asked questions

Where can I buy the LC1F1000FD?

We source the LC1F1000FD to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ with your quantity and delivery needs.

What is the rated operational current of the LC1F1000FD?

The rated operational current is 1250 A in AC-3 duty (motor switching) at <= 440 V AC. The conventional free air thermal current is also 1250 A at 40 °C.

What standards does the LC1F1000FD comply with?

The contactor complies with EN 60947-4-1 and IEC 60947-4-1 (contactor standard), plus EN/IEC 60947-1 (general rules). Rated insulation voltage is 1000 V per IEC 60947-4-1, with an impulse withstand voltage of 8 kV.

MPN
LC1F1000FD