Skip to main content
Schneider Electric LC1F1000W7 — Contactors

TeSys F LC1F1000W7 Contactor, 3P AC-3 1000 A, 265-277 V AC C

MPNLC1F1000W7
Obsolete

Schneider Electric TeSys F, LC1F1000W7, 3P NO contactor, AC-3 rated 1000 A at ≤440 V, coil 265-277 V AC 40-400 Hz, plate mount, IP20 front face.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1F1000W7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control Resistive load

Ratings & Performance

LC1F1000W7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 440 V AC 50/60 Hz
Utilisation categoryAC-3 AC-1

Contacts & Poles

LC1F1000W7 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1F1000W7 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH

Approvals

LC1F1000W7 — Approvals
ParameterValue
StandardsIEC 60947-1 EN 60947-4-1 IEC 60947-4-1 EN 60947-1

Mechanical

LC1F1000W7 — Mechanical
ParameterValue
Width438 mm
Height332 mm
Depth238.6 mm

Product details

It carries a rated operational current of 1000 A at ≤440 V AC in AC-3 duty (1250 A conventional free-air thermal current Ith at 40 °C), and can switch motors up to 670 kW at 440 V or 560 kW at 380-400 V three-phase. The coil is rated 265-277 V AC at 40-400 Hz, with closing time 40-80 ms and opening 100-200 ms.

Mounts to a plate (not DIN rail) — plan for the footprint: 438 mm wide, 332 mm tall, 238.6 mm deep. Power connections use bars (3 or 4 cables); control wiring is screw-clamp terminals accepting 1-4 mm² flexible or solid. The front face carries IP20 protection with shrouds per IEC 60529 and VDE 0106. Operating altitude up to 3000 m without derating; ambient air temperature for operation -5 to 40 °C, with permissible extended range -40 to 60 °C around the device.

Conforms to IEC 60947-1, IEC 60947-4-1, EN 60947-1, and EN 60947-4-1. Rated insulation voltage 1000 V per IEC 60947-4-1 (1500 V per VDE 0110 group C), impulse withstand voltage 8 kV, overvoltage category III. Short-time withstand current 10 kA for 10 s at 40 °C. Protective treatment TH for tropical environments.

Frequently asked questions

What is the rated operational current of LC1F1000W7?

The LC1F1000W7 is rated 1000 A in AC-3 duty at ≤440 V AC, with a conventional free-air thermal current Ith of 1250 A at 40 °C.

What motor power can LC1F1000W7 handle?

It handles motors up to 670 kW at 440 V, 630 kW at 415 V, 560 kW at 380-400 V, and 315 kW at 220-230 V, all three-phase.

Where can I buy LC1F1000W7?

The LC1F1000W7 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
LC1F1000W7