Skip to main content
Schneider Electric LC1F1154P5 — Contactors

Schneider LC1F1154P5 TeSys F Contactor, 200 A AC-1, 4 NO, 23

MPNLC1F1154P5
Obsolete

Schneider Electric TeSys F, LC1F1154P5, 4-pole contactor, 200 A AC-1, 4 NO, 230 VAC 50 Hz coil, plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F1154P5 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F1154P5 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1
LC1F1154P5 — Contacts & Poles
ParameterValue
Pole configuration4P
LC1F1154P5 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH
LC1F1154P5 — Approvals
ParameterValue
StandardsIEC 60947-4-1 IEC 60947-1 EN 60947-1 EN 60947-4-1 JIS C8201-4-1
LC1F1154P5 — Mechanical
ParameterValue
Width200.5 mm
Height162 mm
Depth171 mm

Product details

TeSys F 4-pole contactor — 200 A AC-1, 230 VAC coil

The Schneider Electric LC1F1154P5 is a TeSys F 4-pole contactor rated for 200 A in AC-1 utilisation category (resistive loads) at ≤440 V, with 4 normally-open power poles and a 230 V AC 50 Hz control coil. This contactor is designed for plate mounting and handles resistive load switching — think heating banks, lighting stages, or transformer primary circuits where inrush is minimal and the load current stays continuous. The 200 A AC-1 rating means it can carry and break that current continuously under resistive conditions; the 4 NO pole configuration gives you four independent switching paths, each rated for the full 200 A when paralleled or split across separate load groups.

Rated operational current of 200 A at ≤440 V in AC-1 duty — this is the resistive load rating. If your load is motor (AC-3) or mixed, the contactor's thermal current (Ith) of 200 A at 50 Hz gives a ceiling, but AC-3 derating applies; verify against your motor FLA. Control coil is 230 V AC 50 Hz, with a pick-up range of 0.85–1.1 Uc and drop-out at 0.35–0.55 Uc (at 55 °C). Inrush power is 550 VA at 50 Hz cos φ 0.3; hold-in drops to 45 VA. That matters for transformer-coupled control circuits — the inrush spike can sag a small control transformer. Mechanical durability is 10 million cycles; maximum operating rate is 2400 cycles/hour at 55 °C. For high-speed cycling applications like resistance welding or fast indexing conveyors, that rate sets the limit. Associated fuse recommendations: 125 A aM or 200 A gG at ≤440 V, for short-circuit coordination. IP2X front face with shrouds (IEC 60529 / VDE 0106) — finger-safe from the front when shrouds are fitted. Altitude rating is 3000 m without derating.

Plate-mounted — no DIN-rail clip on this frame size. Dimensions: 162 mm height, 200.5 mm width, 171 mm depth. Power circuit accepts bar (20 x 3 mm), lugs (95 mm²), or bolted connections; control circuit uses screw-clamp terminals for 1–4 mm² flexible or solid. Tightening torque: power circuit 10 N·m, control circuit 1.2 N·m.

Frequently asked questions

Where can I buy the LC1F1154P5 and how is it quoted?

The LC1F1154P5 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time figure is published. Submit an RFQ for a real-time check on the aftermarket.

What are the key ratings of the LC1F1154P5?

200 A rated operational current in AC-1 (resistive loads) at ≤440 V, 4 NO power poles, 230 V AC 50 Hz control coil. Mechanical durability 10 Mcycles, max operating rate 2400 cyc/h at 55 °C. Rated breaking capacity 920 A per IEC 60947-4-1.

MPN
LC1F1154P5