Skip to main content
Schneider Electric LC1F1154P7 — Contactors

Schneider LC1F1154P7 TeSys F Contactor, 200 A AC-1, 4 NO, EO

MPNLC1F1154P7
Obsolete

Schneider Electric TeSys F, LC1F1154P7, 4-pole power contactor, 200 A rated operational current (AC-1), 230 V AC 50/60 Hz coil, plate mount, EOL lifecycle.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F1154P7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F1154P7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1
LC1F1154P7 — Contacts & Poles
ParameterValue
Pole configuration4P
LC1F1154P7 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH
LC1F1154P7 — Approvals
ParameterValue
StandardsIEC 60947-4-1 EN 60947-4-1 EN 60947-1 IEC 60947-1 JIS C8201-4-1
LC1F1154P7 — Mechanical
ParameterValue
Width200.5 mm
Height162 mm
Depth171 mm

Product details

The Schneider Electric LC1F1154P7 is a TeSys F 4-pole power contactor rated for 200 A in AC-1 utilisation category (resistive loads) at up to 440 V, with a 230 V AC control coil. It switches resistive heating banks, lighting, or distribution loads — not motor starting, which would need an AC-3 rated contactor. The 4 NO pole configuration gives you four normally-open main contacts in one package, saving panel space over ganging two 2-pole units.

The 230 V AC control coil draws 770 VA inrush and 8.1 VA holding at 20 °C. The control circuit voltage limits are 0.85 to 1.1 Uc for pickup and 0.2 to 0.55 Uc for dropout at 55 °C. Operating time is 35 ms closing and 130 ms opening at rated control voltage.

Plate-mount only — no DIN-rail clip on this frame. The footprint is 200.5 mm wide by 162 mm tall by 171 mm deep, so plan for a backplate or sub-panel with clearance for the 171 mm projection. Power terminals accept bar (up to 20 x 3 mm busbar) or lugs/ring terminals for up to 95 mm² cable; control terminals are screw-clamp for 1 to 4 mm². Tightening torque is 10 N·m on the power circuit and 1.2 N·m on the control circuit. IP2X finger protection on the front face requires the shrouds.

Designed to IEC 60947-4-1 and EN 60947-4-1 for contactors and motor-starters, plus IEC 60947-1 and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 or 1500 V per VDE 0110 group C. Impulse withstand voltage is 8 kV, overvoltage category III. The protective treatment is TH (tropicalised) for humid environments. Altitude rating is 3000 m without derating.

Frequently asked questions

What compliance documentation does Schneider provide for the LC1F1154P7?

The contactor is designed to IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V (IEC) or 1500 V (VDE 0110 group C). The manufacturer typically provides a declaration of conformity covering these standards; request it with your RFQ.

MPN
LC1F1154P7