Skip to main content
Schneider Electric LC1F1154U7 — Contactors

Schneider Electric LC1F1154U7 TeSys F Contactor, 200 A AC-1,

MPNLC1F1154U7
Obsolete

Schneider Electric TeSys F LC1F1154U7, 4-pole contactor, 200 A AC-1 at ≤440 V, 240 VAC 40-400 Hz coil, plate mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1F1154U7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load

Ratings & Performance

LC1F1154U7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1

Contacts & Poles

LC1F1154U7 — Contacts & Poles
ParameterValue
Pole configuration4P

Environmental

LC1F1154U7 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH

Approvals

LC1F1154U7 — Approvals
ParameterValue
StandardsIEC 60947-4-1 EN 60947-1 JIS C8201-4-1 EN 60947-4-1 IEC 60947-1

Mechanical

LC1F1154U7 — Mechanical
ParameterValue
Width200.5 mm
Height162 mm
Depth171 mm

Product details

TeSys F 4-pole contactor, 200 A AC-1 — EOL sourcing note

The Schneider Electric LC1F1154U7 is a TeSys F 4-pole contactor rated 200 A in AC-1 utilisation category at ≤440 V, making it suited for switching resistive loads like heater banks or lighting in industrial panels. The coil is 240 V AC 40-400 Hz, with a closing time of 35 ms and opening at 130 ms at nominal voltage. This part is in end-of-life (EOL) phase per the manufacturer lifecycle status.

The 200 A AC-1 rating at ≤440 V governs resistive loads — this is not a motor-starting (AC-3) contactor. For motor duty, the AC-1 figure would derate significantly; use the part only for the utilisation category stated. The 4 NO pole configuration (4 normally open power poles) suits applications requiring four independent load circuits, each rated for the full 200 A under AC-1 conditions. Heat dissipation runs 5.9 to 7.2 W total, with 15 W per pole in AC-1 duty — factor this into enclosure thermal calculations. The contactor is plate-mounted, not DIN-rail, so panel layout must accommodate bolted fixing. Rated insulation voltage is 1000 V per IEC 60947-4-1, with an impulse withstand of 8 kV. Overvoltage category III means it is suitable for fixed-installation distribution boards. The IP2X front-face protection (with shrouds) meets IEC 60529 and VDE 0106 for finger-safe touch protection.

The LC1F1154U7 is certified to IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. It carries protective treatment TH for tropical environments. Ambient operating range is -40 to 60 °C, storage -60 to 80 °C, and altitude up to 3000 m without derating.

Frequently asked questions

What compliance documentation does Schneider Electric provide for LC1F1154U7?

The contactor is certified to IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. It carries protective treatment TH for tropical environments and is rated IP2X front-face with shrouds per IEC 60529 and VDE 0106.

Where can I buy LC1F1154U7?

The LC1F1154U7 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN