Schneider Electric LC1F115V5 — Contactors

Schneider Electric LC1F115V5 TeSys F Contactor, 55 kW AC-3

MPNLC1F115V5
Obsolete

Schneider Electric TeSys F contactor, LC1F115V5, 3-pole, 55 kW at 400 V AC-3, 200 A rated, 400 V AC 50 Hz coil, plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F115V5 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load Motor control
LC1F115V5 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-3 AC-1 AC-4
LC1F115V5 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1F115V5 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH
LC1F115V5 — Approvals
ParameterValue
StandardsEN 60947-4-1 EN 60947-1 JIS C8201-4-1 IEC 60947-4-1 IEC 60947-1
LC1F115V5 — Mechanical
ParameterValue
Width163.3 mm
Height162 mm
Depth171 mm

Product details

The LC1F115V5 is a 3-pole contactor from the TeSys F range, rated for 55 kW motor switching at 380–400 V AC in AC-3 duty (the standard category for squirrel-cage motor starting). That 55 kW figure at 400 V is the load the contactor handles in normal starting and running — not the resistive-heater rating, which is higher. For AC-1 resistive loads the thermal current (Ith) is 200 A at 50 Hz, with 15 W dissipation per pole. Control circuit is 400 V AC 50 Hz, with a pickup range of 0.85–1.1 Uc and drop-out between 0.35–0.55 Uc. Inrush is 550 VA at 50 Hz; hold-in drops to 45 VA. Operating time is 23–35 ms closing, 5–15 ms opening — fast enough for most motor control but not for high-speed reversing without interlocking.

This part is in end-of-life (hot) phase — the manufacturer has flagged it for discontinuation. No official successor order code appears in the record. If you are freezing a new design, consider whether a current-production TeSys F variant with the same footprint and ratings can be qualified.

Mounts on a plate — not DIN rail. Dimensions are 162 mm high, 163.3 mm wide, 171 mm deep. Power circuit connections accept bar (up to 20 x 3 mm busbar), ring lugs, or connectors for up to 95 mm² cable. Control circuit uses screw clamp terminals for 1–4 mm² flexible or solid. Tightening torque is 10 N·m on the power circuit, 1.2 N·m on the control circuit. IP2X front face with shrouds per IEC 60529.

Designed to IEC 60947-4-1, IEC 60947-1, EN 60947-4-1, EN 60947-1, and JIS C8201-4-1. Rated insulation voltage 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 group C. Overvoltage category III. Protective treatment TH (tropicalized). Mechanical durability 10 million cycles. Maximum operating rate 2400 cycles per hour at 55 °C. Altitude 3000 m without derating.

Frequently asked questions

Where can I buy LC1F115V5 and get a price?

We source and quote the LC1F115V5 to order against an RFQ. Availability and current pricing are confirmed at the time of your quote request — submit an RFQ through this listing.

What is the closest alternative to LC1F115V5 in the TeSys F family?

No official successor order code is listed. A current-production TeSys F contactor with the same 200 A AC-3 rating and 400 V AC coil may be footprint-compatible, but the exact pin-compatible replacement must be verified against the panel layout and control voltage.

What compliance documentation does Schneider provide for LC1F115V5?

The contactor is designed to IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1. It carries overvoltage category III and protective treatment TH. Specific RoHS/REACH/UL declarations should be requested with the RFQ.

MPN
LC1F115V5