Skip to main content
Schneider Electric LC1F115V5

Schneider Electric LC1F115V5 TeSys F Contactor, 55 kW AC-3

MPN LC1F115V5
Obsolete

Schneider Electric TeSys F contactor, LC1F115V5, 3-pole, 55 kW at 400 V AC-3, 200 A rated, 400 V AC 50 Hz coil, plate mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F115V5 key specifications
ParameterValue
Control circuit typeAC at 50 Hz
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage400 V AC 50 Hz
Insulation voltage ui1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Current200 A (at 115 A (at <55 °C) at <= 440 V AC-3
Breaking capacity920 A conforming to IEC 60947-4-1
Utilization categoryAC-3 AC-1 AC-4
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max60 °C
Temp operating min-40 °C

All specifications

LC1F115V5 additional specifications
ParameterValue
Storage temperature-60...80 °C
Depth171 mm
Width163.3 mm
Height162 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load Motor control
Operating time23...35 ms closing 5...15 ms opening
Operating temperature-40...60 °C
Permissible ambient air temperature around the device60...70 °C at Uc

Product details

The LC1F115V5 is a 3-pole contactor from the TeSys F range, rated for 55 kW motor switching at 380–400 V AC in AC-3 duty (the standard category for squirrel-cage motor starting). That 55 kW figure at 400 V is the load the contactor handles in normal starting and running — not the resistive-heater rating, which is higher. For AC-1 resistive loads the thermal current (Ith) is 200 A at 50 Hz, with 15 W dissipation per pole. Control circuit is 400 V AC 50 Hz, with a pickup range of 0.85–1.1 Uc and drop-out between 0.35–0.55 Uc. Inrush is 550 VA at 50 Hz; hold-in drops to 45 VA. Operating time is 23–35 ms closing, 5–15 ms opening — fast enough for most motor control but not for high-speed reversing without interlocking.

This part is in end-of-life (hot) phase — the manufacturer has flagged it for discontinuation. No official successor order code appears in the record. If you are freezing a new design, consider whether a current-production TeSys F variant with the same footprint and ratings can be qualified.

Mounts on a plate — not DIN rail. Dimensions are 162 mm high, 163.3 mm wide, 171 mm deep. Power circuit connections accept bar (up to 20 x 3 mm busbar), ring lugs, or connectors for up to 95 mm² cable. Control circuit uses screw clamp terminals for 1–4 mm² flexible or solid. Tightening torque is 10 N·m on the power circuit, 1.2 N·m on the control circuit. IP2X front face with shrouds per IEC 60529.

Designed to IEC 60947-4-1, IEC 60947-1, EN 60947-4-1, EN 60947-1, and JIS C8201-4-1. Rated insulation voltage 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 group C. Overvoltage category III. Protective treatment TH (tropicalized). Mechanical durability 10 million cycles. Maximum operating rate 2400 cycles per hour at 55 °C. Altitude 3000 m without derating.

MPN
LC1F115V5