Skip to main content
Schneider Electric LC1F1504F7 — Contactors

Schneider TeSys F LC1F1504F7 Contactor, 250 A AC-1, 110 VAC

MPNLC1F1504F7
Obsolete

Schneider Electric TeSys F series, LC1F1504F7 contactor, 4-pole, 250 A AC-1 at ≤440 V, 110 V AC 40-400 Hz coil, plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F1504F7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F1504F7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1
LC1F1504F7 — Contacts & Poles
ParameterValue
Pole configuration4P
LC1F1504F7 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH
LC1F1504F7 — Approvals
ParameterValue
StandardsIEC 60947-4-1 JIS C8201-4-1 EN 60947-1 IEC 60947-1 EN 60947-4-1
LC1F1504F7 — Mechanical
ParameterValue
Width200.5 mm
Height170 mm
Depth171 mm

Product details

The Schneider Electric LC1F1504F7 is a TeSys F series 4-pole contactor rated for 250 A in AC-1 utilisation category (resistive load) at ≤440 V, with a 110 V AC 40-400 Hz control coil. It switches resistive loads like heaters or lighting banks, not motor starts — the AC-1 rating means it handles steady-state current without the inrush a motor draws. The 4 NO power poles give you four independent make contacts in one package, useful for switching multiple load circuits or a three-phase plus neutral.

The 8 kV impulse withstand voltage (Uimp) and overvoltage category III rating tell you it's designed for fixed-installation distribution panels, not sensitive electronics. Mechanical durability of 10 million cycles gives a long service life in lightly cycled applications; at the maximum operating rate of 2400 cycles/hour at 55 °C, that's over 4000 hours of continuous switching if you push it that hard.

Plate-mounted, not DIN-rail — the 200.5 mm width and 171 mm depth mean it needs a backplate or sub-panel with clearance for the power circuit bolted connections (bar, lugs, or connector up to 120 mm² cable). Control wiring uses screw clamp terminals accepting 1 to 4 mm² flexible or solid. Torque the power connections to 18 N·m and control connections to 1.2 N·m. The IP2X front face with shrouds meets finger-probe protection per IEC 60529 and VDE 0106, so it's safe for open-panel mounting with the shrouds fitted.

Operates from -40 to 60 °C ambient, stores from -60 to 80 °C, and runs at altitudes up to 3000 m without derating. The TH protective treatment means it's tropicalised for humid environments. Standards compliance covers IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1 — the core contactor standard for switching and protection. Rated insulation voltage is 1000 V per IEC 60947-4-1, with a 1500 V rating per VDE 0110 group C.

Frequently asked questions

Where can I buy the LC1F1504F7?

We can source and quote the LC1F1504F7 to order against an RFQ through our independent distribution network. Availability and current pricing are confirmed at quote time.

What is the rated operational current of the LC1F1504F7?

The LC1F1504F7 is rated for 250 A at ≤440 V in AC-1 utilisation category (resistive load). This is the steady-state current it can carry, not a motor-starting rating.

What compliance documentation does the LC1F1504F7 meet?

The LC1F1504F7 complies with IEC 60947-4-1, EN 60947-4-1, JIS C8201-4-1, IEC 60947-1, and EN 60947-1. It carries a rated insulation voltage of 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C.

MPN
LC1F1504F7