Skip to main content
Schneider Electric LC1F1854FE7 — Contactors

Schneider Electric LC1F1854FE7 TeSys F Contactor, 275 A AC-1

MPNLC1F1854FE7
Obsolete

Schneider Electric TeSys F, LC1F1854FE7, 4-pole contactor, 275 A AC-1, 115 V AC 40-400 Hz coil, plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F1854FE7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F1854FE7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC1F1854FE7 — Contacts & Poles
ParameterValue
Pole configuration4P
LC1F1854FE7 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH
LC1F1854FE7 — Approvals
ParameterValue
StandardsEN 60947-1 IEC 60947-4-1 IEC 60947-1 EN 60947-4-1 JIS C8201-4-1
LC1F1854FE7 — Mechanical
ParameterValue
Width208.5 mm
Height174 mm
Depth181 mm

Product details

The Schneider Electric LC1F1854FE7 is a TeSys F 4-pole contactor rated for 275 A at ≤440 V in AC-1 duty (resistive loads). The 115 V AC coil accepts 40-400 Hz control supply, with an inrush of 1070 VA and a hold-in draw of 9.9 VA. This is a plate-mount part — no DIN-rail clip — sized for bolting into a panel or enclosure backplate.

The 275 A AC-1 rating governs resistive loads like heaters or lighting banks. For motor duty (AC-3), the contactor will carry less — the spec table doesn't list an AC-3 current, so size up if you're switching induction motors. The 4 NO pole arrangement means all four poles close together; no built-in auxiliary contacts, so add a side-mount block if you need feedback. The 115 V AC coil operates between 0.85 and 1.1 Uc at 55 °C and drops out between 0.35 and 0.55 Uc — standard for this class.

Integration notes

Plate-mount only — no DIN-rail adapter. Power circuit terminals accept bar (25 x 3 mm busbar), ring lugs, or connectors up to 150 mm² cable. Control circuit uses screw clamp terminals for 1-4 mm² flexible or solid wire. Tightening torque: 1.2 N·m on control, 18 N·m on power. The front face with shrouds achieves IP2X per IEC 60529 and VDE 0106.

Frequently asked questions

What compliance documentation does Schneider provide for LC1F1854FE7?

The contactor is certified to EN 60947-1, IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Overvoltage category III. Protective treatment is TH (tropicalized).

MPN
LC1F1854FE7