Schneider Electric LC1F2254V7

Schneider TeSys F LC1F2254V7 Contactor, 315 A AC-1, 4 NO, 40

MPN LC1F2254V7
Obsolete

Schneider Electric TeSys F series, LC1F2254V7, 4-pole contactor, 315 A AC-1 at ≤440 V, 400 V AC 40–400 Hz coil, plate mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F2254V7 key specifications
ParameterValue
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage690 V AC 50/60 Hz
Coil voltage400 V AC 40...400 Hz
Insulation voltage ui1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Current315 A (at <40 °C) at <= 440 V AC-1
Breaking capacity1800 A conforming to IEC 60947-4-1
Utilization categoryAC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C

All specifications

LC1F2254V7 additional specifications
ParameterValue
Storage temperature-60...80 °C
Depth181 mm
Width208.5 mm
Height197 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load
Operating time35 ms closing at Uc) 130 ms opening at Uc)
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

The Schneider Electric TeSys F LC1F2254V7 is a 4-pole contactor rated for 315 A in AC-1 utilisation category (resistive load) at ≤440 V, 50/60 Hz. The 400 V AC control coil operates at 40–400 Hz with a closing time of 35 ms and opening time of 130 ms at rated control voltage. It is designed for plate mounting and carries IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1 compliance.

The 315 A AC-1 rating governs resistive loads — heaters, lighting banks, or transformer primaries where inrush is minimal. The 4 NO (normally open) power pole configuration means all four poles switch the load; there are no built-in auxiliary contacts. The 400 V AC coil is a non-standard control voltage in many panels (common are 110 V, 230 V, or 24 V DC), so verify the control transformer or PLC output matches before specifying. The plate-mount form factor (181 mm depth, 208.5 mm width, 197 mm height) requires a dedicated backplate or sub-panel — not a standard DIN rail.

Deployment Context

This contactor is sized for industrial control panels switching resistive loads up to 315 A. The plate-mount design and IP20 front face (with shrouds) suit enclosed panel installation where personnel access is limited to qualified electricians. Power circuit connections accept bar, lug-ring, or bolted terminations up to 185 mm² cable or 32×4 mm busbar — typical for main feeder or large heater bank switching. The 8–9.8 W heat dissipation (32 W per pole in AC-1 duty) must be factored into the panel thermal budget to avoid derating at elevated ambient temperatures.

MPN
LC1F2254V7