Skip to main content
Schneider Electric LC1F225P5 — Contactors

Schneider Electric LC1F225P5 TeSys F Contactor, 315 A AC-3,

MPNLC1F225P5
Obsolete

Schneider Electric TeSys F, LC1F225P5, 3-pole contactor, 315 A AC-3, 110 kW at 400 V, 230 V AC 50 Hz coil, plate mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1F225P5 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control Resistive load

Ratings & Performance

LC1F225P5 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 690 V AC 50/60 Hz
Utilisation categoryAC-4 AC-1 AC-3

Contacts & Poles

LC1F225P5 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1F225P5 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH

Approvals

LC1F225P5 — Approvals
ParameterValue
StandardsIEC 60947-4-1 JIS C8201-4-1 EN 60947-1 EN 60947-4-1 IEC 60947-1

Mechanical

LC1F225P5 — Mechanical
ParameterValue
Width168.5 mm
Height197 mm
Depth181 mm

Product details

The Schneider Electric LC1F225P5 is a 3-pole TeSys F contactor rated for 315 A operational current in AC-3 duty, switching motor loads up to 110 kW at 380–400 V AC. Rated breaking capacity is 1800 A per IEC 60947-4-1, and the contactor is listed for utilisation categories AC-1 (resistive), AC-3 (squirrel-cage motor start/run), and AC-4 (plugging/inching). That means it handles both steady resistive loads and the inductive inrush of motor starting, but AC-4 duty — frequent reversing or jogging — will wear the contacts faster; the mechanical durability of 10 Mcycles gives a sense of the base life before contact maintenance.

The 315 A AC-3 rating is the headline number, but the real fit check is the motor power at your line voltage: 110 kW at 400 V, 129 kW at 500 V, and 63 kW at 230 V. If your motor is 110 kW at 400 V, this contactor lands right on the rating — no headroom for derating if ambient hits 55 °C (the max operating temp). The coil hold-in draw is 55 VA at 50 Hz; the inrush is 805 VA, so the control transformer needs to handle that surge without dropping below 0.85 Uc (196 V for a 230 V coil). Power connections accept bar or lug terminals up to 185 mm² cable; control wiring is screw-clamp, 1–4 mm² flexible or solid. Tightening torque is 35 N·m on the power side and 1.2 N·m on the control side — a torque wrench is non-negotiable for the power lugs to avoid hot spots at 315 A.

Deployment context

Plate-mounted in a motor control centre or panel, this contactor is sized for a 3-pole motor branch circuit. The 181 mm depth and 168.5 mm width mean it fits a standard backplate with generous side clearance for arc flash and cable bending radius.

Frequently asked questions

Where can I buy LC1F225P5 and how do I get a price?

We source LC1F225P5 to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the closest pin-compatible alternative to LC1F225P5?

No official successor order code is listed for this part. Any alternative would need to be validated against the original panel design for footprint, coil voltage, and current rating.

What is LC1F225P5's listed depth?

The depth is 181 mm.

What compliance documentation does this brand provide for LC1F225P5?

The contactor is certified to IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Protective treatment is TH (tropicalised).

MPN