Schneider Electric LC1F5002V7

Schneider TeSys F LC1F5002V7 Contactor, 700 A AC-1, 400 V Co

MPN LC1F5002V7
Obsolete

Schneider Electric TeSys F LC1F5002V7 contactor, 2-pole, 700 A AC-1, 400 V AC 50/60 Hz coil, plate mount, end-of-life status.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F5002V7 key specifications
ParameterValue
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage400 V AC 40...400 Hz
Current700 A (at <40 °C) at <= 440 V AC AC-1
Breaking capacity4000 A conforming to IEC 60947-4-1
Utilization categoryAC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-60...80 °C

All specifications

LC1F5002V7 additional specifications
ParameterValue
Depth232 mm
Width233 mm
Height238 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load
Operating time40...65 ms closing 100...170 ms opening
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

That AC-1 rating means it's designed for resistive loads — heaters, ovens, lighting banks — where the current stays steady through the switching cycle, not the inductive inrush of a motor start. The coil pulls 400 V AC at 40 to 400 Hz, with an inrush of 1100 VA and a hold-in draw of 18 VA once the armature seals. This is a plate-mount contactor, not a DIN-rail snap-on. At 233 mm wide, 238 mm tall, and 232 mm deep, it needs a bolted-down footprint in the panel — plan for the 35 N·m torque spec on the power circuit connections and the bar or ring-lug terminations that handle the 700 A path.

The headline number is 700 A at ≤40 °C in AC-1 duty. The associated fuse sizing is 500 A aM or 800 A gG at up to 440 V — a useful guardrail for the upstream protection. The closing time is 40 to 65 ms, opening 100 to 170 ms — that opening delay is inherent to the AC coil dropout characteristic. Heat dissipation runs 18 W for the coil and 88 W per pole in AC-1 service, so factor that into your enclosure thermal budget. The control circuit is screw-clamp terminals accepting 1 to 4 mm² flexible or solid wire. The power circuit uses bolted bar connections or ring lugs for up to 240 mm² cable — this is a high-current interface that needs proper lug crimping and the specified 35 N·m torque.

Standards and environmental limits

The contactor is certified to IEC 60947-1, IEC 60947-4-1, EN 60947-4-1, EN 60947-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1, with an impulse withstand voltage of 8 kV. Overvoltage category III. The front face with shrouds carries IP20 protection. Operating temperature range is -5 to 55 °C, storage from -60 to 80 °C, and it can operate at altitudes up to 3000 m without derating.