Skip to main content
Schneider Electric LC1F5004P7

Schneider Electric LC1F5004P7 TeSys F Contactor, 700 A AC-1,

MPN LC1F5004P7
Obsolete

Schneider Electric TeSys F, LC1F5004P7, 4-pole contactor, 700 A AC-1, 230 V AC 40-400 Hz coil, plate mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F5004P7 key specifications
ParameterValue
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage230 V AC 40...400 Hz
Insulation voltage ui1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Current700 A (at <40 °C) at <= 440 V AC AC-1
Breaking capacity4000 A conforming to IEC 60947-4-1
Utilization categoryAC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C

All specifications

LC1F5004P7 additional specifications
ParameterValue
Storage temperature-60...80 °C
Depth232 mm
Width288 mm
Height238 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load
Operating time40...65 ms closing 100...170 ms opening
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

The Schneider Electric LC1F5004P7 is a TeSys F 4-pole contactor rated for 700 A in AC-1 utilisation category (resistive loads) at ≤ 440 V AC, with a 230 V AC 40–400 Hz control coil. The four normally open power poles and the AC-1 rating mean it is built for switching resistive heater banks, lighting stages, or transformer primaries — loads where inrush is low and the current stays sinusoidal. It is not a motor-contacting AC-3 device; the AC-1 curve governs the thermal capacity.

This order code is flagged end-of-life (EOL hot). If you are freezing a new design, the TeSys F family still offers active 4-pole contactors in this frame size; cross-check the coil voltage and mounting pattern against the current catalogue.

Plate-mounted, not DIN-rail. The 288 mm width and 238 mm height need a backplate or sub-panel with clearance for the power-circuit busbar (40 x 5 mm bar or 240 mm² lugs). Control-circuit wiring uses screw-clamp terminals accepting 1–4 mm² flexible or solid. Torque the power connections to 35 N·m, control connections to 1.2 N·m. Front-face IP20 with shrouds per IEC 60529 — suitable for enclosed panels where incidental finger contact is the only exposure.

Designed and certified to IEC 60947-4-1 and IEC 60947-1, plus the Japanese JIS C8201-4-1 equivalent. Rated insulation voltage 1000 V per IEC 60947-4-1 (1500 V per VDE 0110 group C), impulse withstand 8 kV, overvoltage category III. The TH protective treatment indicates tropicalisation — suitable for humid or mildly corrosive environments within the -5 to 55 °C operating range.

MPN
LC1F5004P7