Schneider Electric LC1F7804V7 TeSys F Contactor, 1600 A AC-1

MPNLC1F7804V7
Obsolete

Schneider Electric TeSys F, LC1F7804V7, 4-pole contactor, 1600 A AC-1, 400 V AC coil, plate mount, IP20 front face.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1F7804V7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load
LC1F7804V7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1
LC1F7804V7 — Contacts & Poles
ParameterValue
Pole configuration4P
LC1F7804V7 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Protective treatment / pollution degreeTH
LC1F7804V7 — Approvals
ParameterValue
StandardsIEC 60947-4-1 IEC 60947-1 JIS C8201-4-1 EN 60947-1 EN 60947-4-1
LC1F7804V7 — Mechanical
ParameterValue
Width862 mm
Height434 mm
Depth255 mm

Product details

The Schneider Electric LC1F7804V7 is a TeSys F 4-pole contactor rated for 1600 A in AC-1 duty (resistive load) at ≤440 V, making it a high-current switching component for heavy resistive loads like large heating banks or furnace circuits. The 400 V AC control coil draws 2100 VA inrush and 50 VA hold-in, with a drop-out threshold between 0.2 and 0.4 Uc — something to verify if the control supply dips during a brownout. It mounts to a plate, not a DIN rail, so factor in the 862 mm width and 434 mm height when laying out the panel.

The 1600 A rated operational current is specific to AC-1 utilisation category — resistive loads only. Do not apply this contactor to motor (AC-3) or inductive loads without derating; the associated fuse recommendation of 1600 A gG or 800 A aM at ≤440 V gives the upstream protection boundary. The 1000 V rated insulation voltage (IEC 60947-4-1) and 8 kV impulse withstand voltage place it in overvoltage category III, suitable for fixed industrial installations. The 44 W heat dissipation (250 W per pole) needs to be vented in the enclosure — a sealed box with this contactor running near its rating will cook adjacent components.

Plate-mounted with bolted power connections accepting busbars up to 100 x 5 mm. Control circuit uses screw-clamp terminals accepting 1 to 4 mm² flexible or solid wire. Power circuit torque is 58 N.m — a calibrated torque wrench is mandatory here; undertightening creates a hot joint. Operating altitude is 3000 m without derating; storage temperature range is -60 to 80 °C.

Frequently asked questions

What is the rated current of LC1F7804V7?

The rated operational current is 1600 A in AC-1 utilisation category (resistive load) at ≤440 V and <40 °C ambient.

What control voltage does LC1F7804V7 use?

The control circuit voltage is 400 V AC at 40 to 400 Hz, with an operational range of 0.85 to 1.1 Uc and a drop-out range of 0.2 to 0.4 Uc at 55 °C.

Where can I buy LC1F7804V7?

This part is sourced through independent industrial distribution channels. Submit an RFQ for current availability and pricing; quotes are confirmed at order time against the specific quantity and delivery requirements.

What standards does LC1F7804V7 comply with?

It complies with IEC 60947-4-1, IEC 60947-1, JIS C8201-4-1, EN 60947-1, and EN 60947-4-1.

MPN