Skip to main content
Schneider Electric LC1F7804V7

Schneider Electric LC1F7804V7 TeSys F Contactor, 1600 A AC-1

MPN LC1F7804V7
Obsolete

Schneider Electric TeSys F, LC1F7804V7, 4-pole contactor, 1600 A AC-1, 400 V AC coil, plate mount, IP20 front face.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F7804V7 key specifications
ParameterValue
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage400 V AC 40...400 Hz
Insulation voltage ui1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Current1600 A (at <40 °C) at <= 440 V AC AC-1
Breaking capacity6240 A conforming to IEC 60947-4-1
Utilization categoryAC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C

All specifications

LC1F7804V7 additional specifications
ParameterValue
Storage temperature-60...80 °C
Depth255 mm
Width862 mm
Height434 mm
Mechanical life cycles5 Mcycles
ApplicationResistive load
Operating time40...80 ms closing 130...230 ms opening
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

The Schneider Electric LC1F7804V7 is a TeSys F 4-pole contactor rated for 1600 A in AC-1 duty (resistive load) at ≤440 V, making it a high-current switching component for heavy resistive loads like large heating banks or furnace circuits. The 400 V AC control coil draws 2100 VA inrush and 50 VA hold-in, with a drop-out threshold between 0.2 and 0.4 Uc — something to verify if the control supply dips during a brownout. It mounts to a plate, not a DIN rail, so factor in the 862 mm width and 434 mm height when laying out the panel.

The 1600 A rated operational current is specific to AC-1 utilisation category — resistive loads only. Do not apply this contactor to motor (AC-3) or inductive loads without derating; the associated fuse recommendation of 1600 A gG or 800 A aM at ≤440 V gives the upstream protection boundary. The 1000 V rated insulation voltage (IEC 60947-4-1) and 8 kV impulse withstand voltage place it in overvoltage category III, suitable for fixed industrial installations. The 44 W heat dissipation (250 W per pole) needs to be vented in the enclosure — a sealed box with this contactor running near its rating will cook adjacent components.

Plate-mounted with bolted power connections accepting busbars up to 100 x 5 mm. Control circuit uses screw-clamp terminals accepting 1 to 4 mm² flexible or solid wire. Power circuit torque is 58 N.m — a calibrated torque wrench is mandatory here; undertightening creates a hot joint. Operating altitude is 3000 m without derating; storage temperature range is -60 to 80 °C.

MPN