Skip to main content
Schneider Electric LC1F780V7

Schneider Electric LC1F780V7 TeSys F Contactor, 780 A AC-3,

MPN LC1F780V7
Obsolete

Schneider Electric TeSys F series, LC1F780V7, 3-pole contactor, 780 A rated operational current at ≤440 V AC-3, 400 V AC 50/60 Hz coil, plate mount, IP20 front face with shrouds.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F780V7 key specifications
ParameterValue
Motor starter typeDirect on-line contactor
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage400 V AC 40...400 Hz
Current1600 A (at 780 A (at <55 °C) at <= 440 V AC AC-3
Breaking capacity6240 A conforming to IEC 60947-4-1
Utilization categoryAC-1 AC-4 AC-3
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max55 °C
Temp operating min-5 °C

All specifications

LC1F780V7 additional specifications
ParameterValue
Storage temperature-60...80 °C
Depth255 mm
Width702 mm
Height434 mm
Mechanical life cycles5 Mcycles
ApplicationResistive load Motor control
Operating time40...80 ms closing 130...230 ms opening
Operating temperature-5...55 °C
Permissible ambient air temperature around the device-40...70 °C

Product details

The LC1F780V7: The 780 A AC-3 rating governs switching of squirrel-cage motors during starting and running — this is the load current the contactor can make and break repeatedly without excessive contact wear. The AC-4 rating at 110 kW (400 V) covers plugging and inching duty, where the contacts open under full locked-rotor current. For resistive loads (AC-1), the contactor is rated 1600 A thermal current (Ith). Control coil draws 2100 VA inrush at 20 °C, with a hold-in range of 0.85–1.1 times the rated coil voltage (400 V AC). Drop-out occurs between 0.2 and 0.4 Uc — useful to know for brownout ride-through planning. Closing time is 40–80 ms; opening takes 130–230 ms. Heat dissipation runs 44 W total, with 60 W per pole in AC-3 and 250 W per pole in AC-1. That matters for enclosure thermal budgeting — a plate-mounted contactor this size (702 mm wide × 434 mm high × 255 mm deep) needs ventilation or forced airflow above 40 °C ambient.

This is a direct on-line contactor for heavy motor control in industrial panels — think large pumps, compressors, conveyors, and crushers in the 250–500 kW range at 380–440 V. Plate mounting on a backpanel or chassis; the power circuit uses bolted bar connections accepting up to 100 × 5 mm busbars. Control wiring is screw-clamp, 1–4 mm² flexible or solid.

Certified to IEC 60947-1, IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 Group C. Overvoltage category III. IP20 on the front face with shrouds (IEC 60529, VDE 0106). Protective treatment TH for tropical environments.

MPN
LC1F780V7