Skip to main content
Schneider Electric LC1G150BEEA

Schneider Electric LC1G150BEEA TeSys Giga, 3P 24-48V

MPN LC1G150BEEA
Active

Schneider Electric TeSys Giga contactor, 3P, LC1G150BEEA, 24-48 V AC/DC coil, motor power 75 kW at 400 V AC-3e.

$1,013.09 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1G150BEEA key specifications
ParameterValue
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage24...48 V AC 50/60 Hz 24...48 V DC
Insulation voltage ui1000 V
Current275 A (at 150 A (at <140 °F (60 °C)) at <= 440 V AC-3
Breaking capacity1280 A at 440 V
Utilization categoryAC-1 AC-3 AC-3e AC-4 AC-5 a AC-5b AC-6 a AC-6b AC-8 a AC-8b DC-1 DC-3 DC-5
Terminal pitch1.4 in (35 mm)
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max60 °C
Temp operating min-25 °C

All specifications

LC1G150BEEA additional specifications
ParameterValue
Storage temperature-76...176 °F (-60...80 °C)
ColorDark grey
Depth7.6 in (193 mm)
Width4.3 in (108 mm)
Height10.04 in (255 mm)
Mechanical life cycles8 Mcycles
ApplicationPower switching Motor control
Operating time40...70 ms closing 15...50 ms opening
Operating temperature-13...140 °F (-25...60 °C)
Permissible ambient air temperature around the device-40...158 °F (-40...70 °C) at Uc

Product details

Contactor role and key ratings

The Schneider LC1G150BEEA is a 3-pole TeSys Giga contactor rated for motor switching in AC-3e duty at 75 kW on a 400 V line, with a 24–48 V AC/DC coil. Built-in bidirectional peak limiting holds the coil inrush to 220 W DC, and the drop-out range (15–50 ms opening) avoids nuisance chatter during dips. Mechanical durability is 8 million cycles; the contactor can cycle 600 times per hour in AC-3 and AC-3e, 150 per hour in AC-4. That tells you it can handle high-rate motor starts without wearing out early.

Where and how it fits

Mounts on a plate (not rail). Power terminals accept bars (25x6 mm) or ring lugs up to 185 mm²; control circuit uses push-in terminals for 0.2–2.5 mm² stranded or solid. Tightening torque for power connections is 18 N·m. Front face with shrouds gives IP2X protection (IEC 60529). The TH protective treatment (tropicalization) handles humid environments. Associated fuse recommendation: 160 A aM or 315 A gG for short-circuit coordination.

Compliance and sourcing posture

Lifecycle stage is current — no end-of-life notice. It carries UL 60947-4-1, CSA, IEC, and JIS certifications, qualifying it for panels in North America, Europe, and Japan. Sourced to order against RFQ. This is an active catalog part; lead time and pricing depend on your volume and preferred region. Submit an RFQ to lock a line for your BOM.

MPN
LC1G150BEEA