Schneider Electric LC1G2254EHEN

LC1G2254EHEN Contactor, 225 A AC-3, 4-Pole

MPNLC1G2254EHEN
Active

Schneider Electric TeSys Giga LC1G2254EHEN, 4-pole power contactor, 225 A AC-3, 48-130 V coil, dark grey enclosure.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

LC1G2254EHEN key specifications
ParameterValue
Range of productTeSys Giga
Product or component typeContactor
Coil voltage48...130 V AC 50/60 Hz 48...130 V DC
Voltage1000 V
Control circuit voltage limitsOperational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))
[Ue] rated operational voltage<= 460 V DC
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current1.8 kA - 10 s 1.0 kA - 30 s 0.85 kA - 1 min 0.56 kA - 3 min 0.44 kA - 10 min
Breaking capacity2050 A at 440 V
[Ie] rated operational current225 A (at 330 A (at <104 °F (40 °C)) at <= 1000 V AC-1
[Ith] conventional free air thermal current330 A (at 104 °F (40 °C))
Inrush power in445 W

All specifications

LC1G2254EHEN additional specifications
ParameterValue
Power dissipation per pole20 W AC-1 - Ith 330 A 8 W AC-3 - Ith 225 A
Inrush power in VA (50/60 hz, AC)640 VA
Hold-in power consumption in7.8 W
Poles description4P
Pole contact composition4 NO
Utilisation categoryAC-3 AC-3e AC-1 AC-5a AC-5b AC-6a AC-6b DC-1 DC-3 DC-5
IP degree of protectionIP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106
Mounting supportPlate
Connection pitch1.4 in (35 mm)
Connections - terminalsPower circuit: bar 2 - busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end
ColorDark grey
Depth7.6 in (193 mm)
Width5.6 in (143 mm)
Height7.6 in (193 mm)
Mechanical durability8 Mcycles
StandardsEN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ
RangeTeSys
CategoryUS10I1222329
Operating time40...70 ms closing 15...50 ms opening
Coil technologyBuilt-in bidirectional peak limiting
Average impedance0.00015 Ohm
Device short nameLC1G
Tightening torque159.3 lbf.in (18 N.m)
Compatibility codeLC1G
Overvoltage categoryIII
Protective treatmentTH
Contactor applicationPower switching
Mechanical robustnessVibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed
Associated fuse rating250 A aM at 200 A aM at 400 A gG at 400 A UL Type J at <= 600 V
Maximum operating rate600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1
Safety reliability levelB10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms rated making capacity2720 A at 440 V
Auxiliary contact composition1 NO + 1 NC
Ambient air temperature for storage-76...176 °F (-60...80 °C)
Ambient air temperature for operation-13...140 °F (-25...60 °C)
Permissible ambient air temperature around the device-40...158 °F (-40...70 °C) at Uc

Product details

That 225 A figure (: AC-3 Ith) is the one you'll spec against a motor's full-load amps — not the 330 A AC-1 resistive number. Coil is dual-voltage: 48 to 130 V AC or DC, so one part covers both line and control circuits in a mixed panel. Mechanical durability is 8 million cycles, and the contactor is rated for vibrations up to 4 gn closed and shocks of 15 gn — meaning it stays pulled in on a portable generator skid or a compressor baseplate. The integral bidirectional peak-limiting coil technology reduces inrush to 445 W DC, which keeps power supply sizing predictable.

Power circuit terminals accept busbar cross-section up to 25 x 6 mm or ring lugs up to 185 mm². Control circuit uses push-in terminals sized for 0.2 to 2.5 mm², which matches common PLC output wiring. Mounting is plate-mount with a 35 mm pitch between poles — plan for the 193 mm depth when laying out the backplate. IP2X with shrouds: safe for front-face access inside a locked panel. Associated fuse recommendations: 250 A aM or 400 A gG for short-circuit protection at 600 V, with a UL Type J option. Rated making capacity is 2720 A at 440 V, breaking capacity 2050 A at 440 V — figures that matter for coordination studies on high-fault panels.

Listed to EN/IEC 60947-4-1 and -5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, plus JIS and UL appliance standards (UL 60335). Overvoltage category III. The protective treatment 'TH' indicates tropicalisation for humid environments. Standards compliance covers the documentation a tender buyer typically requires.

Frequently asked questions

What is LC1G2254EHEN's listed color?

The enclosure is dark grey.

What is LC1G2254EHEN's listed depth?

It is 7.6 inches (193 mm) deep.

What compliance documentation is available for LC1G2254EHEN?

The contactor complies with EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS standards, among others.