Specifications

LC1K0601B5 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control
LC1K0601B5 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-3e AC-4
LC1K0601B5 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K0601B5 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K0601B5 — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ
LC1K0601B5 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC1K0601B5 is a 3-pole contactor from the TeSys K series, rated for 6 A in AC-3 and AC-3e utilization categories at up to 440 V. That AC-3 rating means it's built for starting and stopping squirrel-cage motors — the standard duty for a contactor this size. The 24 V 50 Hz coil keeps it in the common control-voltage range for panel designs in regions using 50 Hz mains.

The AC-3 and AC-3e ratings at 6 A tell you this contactor handles motor inrush (typically 6–8x FLA) during starting, then breaks the running current. The AC-4 rating at 36 A (up to 440 V) covers plugging or inching duty — but note the electrical durability drops to 0.05 Mcycles there, so it's not meant for frequent reversing without a derating check. The 1.3 Mcycles at AC-3 is solid for a compact contactor. The single NC auxiliary contact is instantaneous, not timed — useful for a feedback signal to a PLC or to seal in a holding circuit. Minimum switching capability is 5 mA at 17 V, so it'll reliably sense dry contacts or low-power logic inputs without needing a wetting current booster.

Screw clamp terminals accept one or two conductors from 0.34 to 4 mm², solid or flexible with ferrules. The IP20 finger-safe protection (per VDE 0106) means it's safe for open-panel installation behind a locked door.

Frequently asked questions

What standards does the LC1K0601B5 comply with?

It complies with EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and the glow-wire requirements of IEC 60335-1 and IEC 60335-2-40 / UL 60335-2-40.

What is the depth of the LC1K0601B5?

The depth is 57 mm.

What is the range of the LC1K0601B5?

It belongs to the TeSys range.

MPN
LC1K0601B5