Skip to main content
Schneider Electric LC1K0901B5

Schneider Electric LC1K0901B5 TeSys K Contactor, 9A AC-3, 24

MPN LC1K0901B5
Obsolete

Schneider Electric TeSys K LC1K0901B5, 3-pole contactor, 9 A AC-3/AC-3e, ≤440 V, 1 NC auxiliary contact, 24 V 50 Hz coil, screw clamp terminals.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1K0901B5 specifications
ParameterValue
Main product or component typeContactor
Utilization categoryAC-3 AC-3e AC-1 AC-4
IP ratingIP20
Temp storage max80 °C
Temp storage min-50 °C
Storage temperature-50...80 °C
Depth57 mm
Width45 mm
Height58 mm
Electrical life cycles1.3 Mcycles 9 A AC-3 at Ue 1.3 Mcycles 9 A AC-3e at Ue 0.16 Mcycles 20 A AC-1 at Ue 0.02 Mcycles 54 A AC-4 at Ue <= 440 V
Mechanical life cycles10 Mcycles
ApplicationResistive load Motor control
Operating time10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing

Product details

The Schneider Electric LC1K0901B5 is a TeSys K series 3-pole contactor rated for motor control at 9 A in AC-3 and AC-3e duty up to 440 V, with a 24 V 50 Hz coil and one normally-closed auxiliary contact. It carries global approvals including EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1, so it fits panels destined for North America, Europe, or Asia without requalification.

AC-3e extends that to energy-efficient motors with higher inrush. Electrical durability at 9 A AC-3 is 1.3 million cycles, which covers most conveyor and pump duty cycles for years. For resistive loads (AC-1) it handles 20 A, and for plugging/inching (AC-4) it is rated 54 A but with only 20,000 cycles — so use AC-4 sparingly, not for continuous jogging. The coil draws 30 VA inrush and 4.5 VA hold-in at 20 °C, dissipating 1.3 W. That heat is low enough to pack multiple contactors on a DIN rail without forced cooling. The control voltage limits are 0.8...1.15 Uc operational, with dropout at ≥0.20 Uc below 50 °C — so it stays pulled in through brownouts down to about 19 V. The single NC auxiliary contact is instantaneous, rated for signalling down to 5 mA and 17 V minimum switching — enough for PLC digital inputs but not for dry-contact logic at lower levels.

Mounts on plate or rail; screw-clamp terminals accept 1.5...4 mm² solid or 0.34...2.5 mm² flexible with ferrule, torqued to 0.8...1.3 N·m. IP20 finger-safe per VDE 0106, so it can sit in an open panel behind a locked door.

MPN
LC1K0901B5