Skip to main content
Schneider Electric LC1K12106L7

Schneider LC1K12106L7 TeSys K Contactor, 3P, 12A AC-3, 200-2

MPN LC1K12106L7
Obsolete

Schneider Electric TeSys K contactor, LC1K12106L7, 3-pole, 12 A AC-3/AC-3e at 440 V, 1 NO auxiliary contact, 200-208 V AC coil, DIN-rail or plate mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1K12106L7 specifications
ParameterValue
Main product or component typeContactor
Utilization categoryAC-3 AC-3e AC-1 AC-4
IP ratingIP2X
Temp storage max80 °C
Temp storage min-50 °C
Storage temperature-50...80 °C
Depth57 mm
Width45 mm
Height58 mm
Electrical life cycles1.3 Mcycles 12 A AC-3 at Ue 1.3 Mcycles 12 A AC-3e at Ue 0.3 Mcycles 20 A AC-1 at Ue 0.02 Mcycles 72 A AC-4 at Ue <= 440 V
Mechanical life cycles10 Mcycles
ApplicationResistive load Motor control
Operating time10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing

Product details

The Schneider Electric LC1K12106L7 is a TeSys K three-pole contactor rated for 12 A in AC-3 and AC-3e utilisation categories at 440 V, with a 200-208 V AC coil and one normally open instantaneous auxiliary contact. It carries approvals under EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1, plus appliance standards IEC 60335-1 and UL 60335-2-40 — meaning it is accepted in industrial control panels and HVAC equipment across North America, Europe, and Asia.

Electrical durability at that duty is 1.3 million cycles, which is typical for a compact contactor in light industrial use. The AC-1 resistive rating is 20 A, but that's for heater or lamp loads, not motors. The 200-208 V AC coil operates across 0.8 to 1.15 times the control voltage (160-239 V) and drops out reliably above 20% of Uc (about 40 V). Inrush is 30 VA, hold-in is 4.5 VA — the coil draws 1.3 W steady-state, so it won't overheat a crowded panel. Mechanical durability is 10 million cycles, and the contactor is rated for 3600 operations per hour — fast enough for repetitive cycling on a packaging line or conveyor. The built-in auxiliary is one NO instantaneous contact, minimum switching 5 mA at 17 V — sufficient for signalling a PLC input or status lamp.

MPN