Skip to main content
Schneider Electric LC1K16016L7 — Contactors

Schneider TeSys K LC1K16016L7 Contactor, 3P, 16A AC-3, 200-2

MPNLC1K16016L7
Obsolete

Schneider Electric TeSys K contactor, LC1K16016L7, 3-pole, 16 A AC-3/AC-3e at 440 V, 200-208 V AC coil, 1 NC auxiliary contact.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC1K16016L7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control
LC1K16016L7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-3e
LC1K16016L7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K16016L7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94
LC1K16016L7 — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ
LC1K16016L7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric TeSys K LC1K16016L7 is a 3-pole contactor rated for motor control in AC-3 and AC-3e duty at 16 A up to 440 V. The 200-208 V AC coil pulls in at 30 VA inrush and holds at 4.5 VA, dissipating 1.3 W steady-state. The part carries a single normally-closed instantaneous auxiliary contact.

The IP2X finger-safe front (per VDE 0106) means it's fine inside a closed panel but not for exposed mounting. Operating temperature range is -25 to 50 °C, storage from -50 to 80 °C, and it's rated for use up to 2000 m without derating.

Frequently asked questions

What are the key ratings for this contactor?

It is a 3-pole contactor rated 16 A in AC-3/AC-3e duty at 440 V, with a 200-208 V AC coil. It includes one normally-closed auxiliary contact and is rated for 1.3 million electrical cycles at that load.

What compliance certifications does this part carry?

It is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1, with additional compliance to IEC 60335 appliance standards. Flame retardance is V1 per UL 94.

What is the mounting and connection style?

It mounts on a DIN rail or plate. Connections are via lugs-ring terminals with a tightening torque of 0.8 to 1.3 N·m. Dimensions are 45 mm wide, 58 mm tall, and 57 mm deep.

MPN
LC1K16016L7