Schneider LC1K1610L7 TeSys K Contactor, 3P, 16A AC-3, 200-20

MPNLC1K1610L7
Obsolete

Schneider Electric TeSys K contactor, 3-pole, 16 A AC-3/AC-3e at 440 V, 1 NO auxiliary contact, 200...208 V AC coil, screw clamp terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1K1610L7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control

Ratings & Performance

LC1K1610L7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-3e

Contacts & Poles

LC1K1610L7 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1K1610L7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94

Approvals

LC1K1610L7 — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ

Mechanical

LC1K1610L7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC1K1610L7 is a three-pole contactor from the TeSys K series, rated for motor control in AC-3 and AC-3e utilisation categories. AC-3e adds an energy-efficiency classification for motors meeting IEC 60034-30 IE2 and above, so this contactor is sized for a motor drawing up to 16 A in that duty. The coil is wound for 200...208 V AC, 50/60 Hz, with an operational voltage range of 0.8 to 1.15 times the control supply voltage (Uc) and a drop-out threshold of 20 % Uc. Inrush power is 30 VA at 20 °C, holding at 4.5 VA — the coil's thermal dissipation is 1.3 W, which matters for enclosure heat rise when multiple contactors are ganged in a panel.

Depth is 57 mm, so it clears a 60 mm deep enclosure backplate with room for wiring. Screw clamp terminals accept 1.5...4 mm² solid or 0.34...2.5 mm² flexible with ferrule; tightening torque is 0.8...1.3 N·m using a No 2 Phillips or flat 6 mm driver. IP2X finger protection per VDE 0106. The contactor carries one instantaneous NO auxiliary contact. For signalling circuits, minimum switching is 5 mA at 17 V — enough for a PLC input but not for dry-contact low-level logic without verifying the load matches. B10d for the contactor under nominal load is 1,369,863 cycles per EN/ISO 13849-1, which qualifies it for safety-related control circuits up to that reliability level.

The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. It also meets the glow-wire and flame-retardance requirements of IEC 60335-1 Clause 30.2 and IEC 60335-2-40 Annex JJ for appliance applications. Flame retardance is V1 per UL 94. The protective treatment is TC per IEC 60068 and DIN 50016, meaning it is tested for tropical climate resistance — relevant for export or high-humidity installations.

Frequently asked questions

What is the closest alternative to the LC1K1610L7 in the TeSys K family?

Within the TeSys K range, the closest peer is the LC1K0910L7 — same coil voltage and auxiliary configuration, but rated 9 A AC-3 instead of 16 A. The LC1K1610L7 is the higher-current variant for the same frame size and footprint. No pin-compatible alternative exists outside the TeSys K series without rewiring or re-panelling.

What compliance documentation is available for the LC1K1610L7?

The contactor carries UL, CSA, and JIS certifications per the listed standards. The manufacturer provides a Declaration of Conformity for the IEC/EN standards and a UL Recognized Component mark. RoHS and REACH compliance documentation is available through the standard product support channel.

MPN