Schneider Electric LC1K1610Q7 — Contactors

Schneider Electric LC1K1610Q7 TeSys K Contactor, 3P, 16A AC-

MPNLC1K1610Q7
Active

Schneider Electric TeSys K contactor, 3-pole, 16 A AC-3 ≤ 440 V, 1 NO auxiliary contact, 380...400 V AC 50/60 Hz coil, screw clamp terminals.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1K1610Q7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationMotor control

Ratings & Performance

LC1K1610Q7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-3e

Contacts & Poles

LC1K1610Q7 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1K1610Q7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94

Approvals

LC1K1610Q7 — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ

Mechanical

LC1K1610Q7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

Part identity and motor duty rating

The LC1K1610Q7 is a TeSys K contactor from Schneider Electric, a 3-pole device (3 NO power poles) rated for motor control in AC-3 and AC-3e utilisation categories up to 440 V, carrying a 16 A operational current. Coil inrush is 30 VA at 20 °C, holding at 4.5 VA — a standard draw for this frame size.

Standards coverage and compliance documentation

This contactor carries approvals across EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and the appliance-specific IEC 60335-1 / 60335-2-40 (Annex JJ) and UL 60335-2-40 (Annex JJ). That last set matters if the contactor ends up inside HVAC equipment — the standard covers contactors used in heat-pump and air-conditioning circuits. Flame retardance is V1 per UL 94.

Wiring, mounting, and environmental limits

Screw clamp terminals accept one or two conductors: 1.5...4 mm² solid, 0.75...4 mm² flexible without ferrule, or 0.34...2.5 mm² flexible with ferrule. Tightening torque is 0.8...1.3 N·m (Philips No 2, flat 6 mm, or Pozidriv No 2). Operating temperature range is -25...50 °C, storage -50...80 °C. Altitude derating starts above 2000 m. The IP2X finger-protection rating (VDE 0106) is typical for enclosed panel mounting — not for open washdown environments. Heat dissipation is 1.3 W at rated duty.

Auxiliary contact and signalling circuit

One instantaneous NO auxiliary contact is built in. The signalling circuit can handle up to 400 Hz and switches down to 5 mA at 17 V minimum, so it works with low-level PLC inputs or pilot lights. Insulation resistance for the signalling circuit is rated at 10 MΩ. Safety reliability figures per EN/ISO 13849-1: B10d of 1,369,863 cycles under nominal load, and 20,000,000 cycles under mechanical load only. Mechanical durability is 10 million cycles; electrical durability at 16 A AC-3 / AC-3e ≤440 V is 1.3 million cycles.

Frequently asked questions

What standards does the LC1K1610Q7 comply with?

It complies with EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, IEC 60335-1 Clause 30.2, IEC 60335-2-40 Annex JJ, and UL 60335-2-40 Annex JJ. Flame retardance is V1 per UL 94.

What is the coil voltage and power consumption?

The coil is 380...400 V AC 50/60 Hz. Inrush power is 30 VA at 20 °C; holding power is 4.5 VA at 20 °C. There is no built-in suppressor module.

What is the closest alternative in the TeSys K family?

Within the same TeSys K frame, the closest functional alternative would be the LC1K1610Q7 itself — there is no pin-compatible variant with a different coil voltage that shares the same 16 A AC-3 rating and 1 NO auxiliary. A coil-voltage variant (e.g., 24 V AC or 230 V AC) uses the same base contactor but requires a different order code. For a higher auxiliary count, a TeSys K with 1 NO + 1 NC or 2 NO auxiliaries exists in the same mechanical footprint.

MPN
LC1K1610Q7