Skip to main content
Schneider Electric LC2K06017V7 — Contactors

TeSys K LC2K06017V7 reversing contactor, 3P, 6A AC-3, 400V A

MPNLC2K06017V7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 6 A, 1 NC, 400 V AC coil, preassembled with reversing power busbar, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K06017V7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K06017V7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3
LC2K06017V7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K06017V7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K06017V7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The LC2K06017V7 is a TeSys K reversing contactor from Schneider Electric — a 3-pole, 3 NO power pole unit rated for AC-3 duty up to 6 A at 440 V and AC-4 duty for reversing motor control. The coil is 400 V AC, and the auxiliary contact complement is 1 NC. AC-3 rating (6 A at 440 V) covers starting and switching off squirrel-cage motors under load — the typical duty for conveyors, pumps, and fans. Rated operational voltage on the power circuit is 690 V AC 50/60 Hz, so it can handle 480 V or 600 V line supplies within the AC-3 envelope, though the 6 A AC-3 rating is specified at ≤440 V. The signalling circuit isolation is tested to 10 MΩ.

If you need a drop-in reversing contactor for a TeSys K panel layout, the closest functional match would be a current TeSys K or TeSys Deca reversing contactor with the same coil voltage and pole count — but verify the busbar footprint and auxiliary stack, because the mechanical interlock assembly changed across generations.

That depth is the key constraint in shallow enclosures or when mounting alongside other contactors on a DIN rail — the reversing busbar adds some projection beyond the base contactor body. IP20 finger-safe terminals per VDE 0106. Altitude derating kicks in above 2000 m. The flame retardance rating meets UL 94 V1 and NF F 16-101/102, which matters for rail and transit applications. Mechanical robustness: the contactor holds closed through 10 Gn shocks on Y and Z axes (11 ms half-sine) and 4 Gn vibration closed across 5–300 Hz. That's enough for most industrial panels but not for extreme mobile or off-road gear without additional isolation.

Frequently asked questions

What replaces the LC2K06017V7?

No official successor order code is published. A current TeSys K or TeSys Deca reversing contactor with a 400 V AC coil and 3-pole, 6 A AC-3 rating is the functional equivalent, but verify the busbar footprint and auxiliary contact arrangement before committing the panel layout.

What are the key ratings for this reversing contactor?

AC-3 rated 6 A at ≤440 V, AC-4 rated for reversing duty, coil 400 V AC, 3 NO power poles, 1 NC auxiliary contact. Power circuit rated up to 690 V AC 50/60 Hz. IP20 protection.

What compliance documentation does Schneider provide for the LC2K06017V7?

The part carries UL 94 V1 flame retardance, NF F 16-101/102 compliance for rail, and IEC 60068 shock/vibration testing. Protective treatment conforms to IEC 60068 and DIN 50016. No RoHS/REACH statement is listed in this record.

MPN
LC2K06017V7