Schneider Electric TeSys K reversing contactor, LC2K0601P72, 3P, 6 A AC-3/AC-3e at 440 V, 1 NC, 230 V AC coil with integral suppression device, preassembled with reversing power busbar.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC2K0601P72 specifications
ParameterValue
Main product or component typeReversing contactor
Utilization categoryAC-4 AC-3 AC-3e
IP ratingIP20
Temp storage max80 °C
Temp storage min-50 °C
Temp operating max50 °C
Temp operating min-25 °C
Storage temperature-50...80 °C
Depth57 mm
Width90 mm
Height58 mm
ApplicationMotor control
Operating temperature-25...50 °C

Product details

The Schneider Electric LC2K0601P72 is a TeSys K reversing contactor — a 3-pole unit rated 6 A in AC-3 (motor) duty at 440 V, with a 230 V AC coil and an integral suppression device built in. It ships preassembled with the reversing power busbar, so you mount it as one piece rather than wiring two contactors and a mechanical interlock separately. The utilisation categories cover AC-3 (squirrel-cage motor starting), AC-3e (high-efficiency motor start), and AC-4 (plugging/inching). The 6 A AC-3 rating means it handles motor inrush without welding the main poles. The 1 NC auxiliary is wired into the reversing interlock circuit out of the box.

For a 400 V three-phase motor, 6 A AC-3 corresponds roughly to a 2.2–3 kW load, depending on efficiency class. The flame retardance meets V1 per UL 94 and NF F 16-101/102, which is the rail-transport fire-smoke standard. Operating ambient is -25 to 50 °C, storage -50 to 80 °C. Shock and vibration ratings are given for both closed and open contactor states — the closed contactor holds through 10–15 Gn shocks depending on axis, which matters for mobile or rail-mounted gear.

The 3 NO main poles and 1 NC auxiliary are the contact complement; the NC is already committed to the reversing logic. The 230 V AC coil draws its rated inrush and hold current from the control transformer. The integral suppression device (RC snubber) is already in place across the coil — no external diode or varistor needed, which saves a wiring step and a DIN-rail slot.

No official successor or alternative order code is listed; the LC2K0601P72 is the active variant for this coil voltage and auxiliary configuration. If you are validating a new design, the TeSys K series is current and supported.

MPN