Skip to main content
Schneider Electric LC2K0610P72 — Contactors

Schneider TeSys K LC2K0610P72 reversing contactor, 6A AC-3,

MPNLC2K0610P72
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 6 A, 1 N/O, 230 V AC coil, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K0610P72 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K0610P72 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3 AC-3e
LC2K0610P72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K0610P72 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K0610P72 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC2K0610P72 is a TeSys K reversing contactor — a 3-pole device preassembled with a reversing power busbar, designed for motor control in the AC-3 and AC-4 utilisation categories. Its headline rating is 6 A at ≤440 V AC in AC-3 duty, meaning it handles reversing of small three-phase induction motors up to that current level. The coil is 230 V AC, 50/60 Hz. A single N/O auxiliary contact is built in.

The contactor measures 90 mm wide by 58 mm high by 57 mm deep — a compact footprint for a reversing pair, since the mechanical interlock and busbar are preassembled. IP20 finger-safe terminals (per VDE 0106) suit enclosed control panels where the contactor is not directly exposed to washdown or dust. Operating temperature range is -25 to 50 °C; storage from -50 to 80 °C. Mounting altitude is 2000 m without derating.

Mechanical and environmental robustness

Rated for shock: 10 Gn on Y and Z axes (contactor closed), 6 Gn on X (opened), per IEC 60068-2-27. Vibration resistance: 4 Gn closed, 2 Gn opened, 5–300 Hz per IEC 60068-2-6. Flame retardance meets V1 per UL 94 and Requirement 2 per NF F 16-101/102. Protective treatment conforms to IEC 60068 and DIN 50016 for tropical environments.

Frequently asked questions

What is the closest pin-compatible alternative to LC2K0610P72?

There is no official successor order code recorded for this part. A current-production TeSys K or TeSys D reversing contactor with the same coil voltage (230 V AC), pole count (3P), and auxiliary (1 N/O) would be the logical starting point, but the exact form-fit-function equivalence must be verified against the mounting dimensions and busbar arrangement.

What are the key ratings of LC2K0610P72?

3-pole reversing contactor rated 6 A in AC-3 duty at ≤440 V AC, with a 230 V AC coil. One N/O auxiliary contact. IP20 protection. Operating temperature -25 to 50 °C.

MPN
LC2K0610P72