Skip to main content
Schneider Electric LC2K0610V7

Schneider LC2K0610V7 TeSys K Reversing Contactor, 3P, 6A, 40

MPN LC2K0610V7
Obsolete

Schneider Electric TeSys K reversing contactor, LC2K0610V7, 3P, AC-3/AC-3e ≤440V 6A, 1NO, 400V AC coil.

$113.99 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC2K0610V7 specifications
ParameterValue
Main product or component typeReversing contactor
Utilization categoryAC-3 AC-3e AC-4
IP ratingIP20
Temp storage max80 °C
Temp storage min-50 °C
Temp operating max50 °C
Temp operating min-25 °C
Storage temperature-50...80 °C
Depth57 mm
Width90 mm
Height58 mm
ApplicationMotor control
Operating temperature-25...50 °C

Product details

Rated AC-3/AC-3e at 6 A up to 440 V, it handles the standard reversing duty for small three-phase motors: conveyors, hoists, or any load that needs forward/reverse switching. The 400 V AC coil matches common European control voltages, and the 1 NO auxiliary contact gives one feedback signal to the PLC or status lamp.

At 6 A AC-3, this contactor is sized for motors up to roughly 2.2 kW at 400 V three-phase. The AC-3e rating extends the same duty to energy-efficient motors with slightly higher inrush. AC-4 covers plugging and inching, so the contactor can handle frequent reversals without derating — relevant for the reversing application it was built for.

Integration notes

IP20 finger-safe protection (VDE 0106) means it is suitable for enclosed panels where operators do not contact live parts. The preassembled reversing busbar eliminates one wiring step: just land the incoming three-phase supply and the motor leads to the output terminals.

Approvals and environmental ratings

Flame retardance meets UL 94 V1 and NF F 16-101/102, so it passes rail and industrial fire-safety requirements. Protective treatment conforms to IEC 60068 and DIN 50016 for corrosion resistance. Operating altitude is 2000 m without derating; ambient temperature range is -25 to 50 °C for operation, -50 to 80 °C for storage. Shock and vibration ratings per IEC 60068-2-27 and IEC 60068-2-6 are documented for both closed and open contactor states — useful if the panel is on a moving platform or near heavy machinery.

MPN