Schneider Electric LC2K09015FE7 — Contactors

TeSys K LC2K09015FE7 Reversing Contactor, 9 A AC-3, 115 VAC

MPNLC2K09015FE7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 9 A, 1 NC, 115 V AC coil, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC2K09015FE7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LC2K09015FE7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-1 AC-3
LC2K09015FE7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K09015FE7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K09015FE7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

Rated 9 A in AC-3 duty at 440 V, it handles reversing motor loads up to that current; the AC-1 resistive rating and AC-4 inching/jogging category are also on the nameplate. The 115 V AC coil pulls in on a standard control voltage, and the single NC auxiliary contact provides a feedback path for the safety circuit.

The AC-1 resistive rating is higher but rarely the limiting factor in a reversing starter. The 115 V AC coil is a common control voltage in North American panels; verify your control transformer matches before committing the line.

Frequently asked questions

What is the closest alternative to the LC2K09015FE7?

No official successor order code is provided in the lifecycle record. A functionally similar TeSys K reversing contactor with a 115 V AC coil and 9 A AC-3 rating would need to be selected by comparing the coil voltage and pole configuration — there is no direct drop-in replacement number from the manufacturer.

What are the key ratings of the LC2K09015FE7?

It is a 3-pole reversing contactor rated 9 A in AC-3 duty at 440 V, with a 115 V AC coil and one NC auxiliary contact. It also carries AC-1 and AC-4 utilisation categories. The IP20 enclosure protects against finger contact.

What compliance documentation exists for the LC2K09015FE7?

The part carries a V1 flame-retardance rating conforming to UL 94, and meets NF F 16-101 and NF F 16-102 for rail-vehicle fire behaviour. IP20 protection is per VDE 0106. No RoHS or REACH statements are listed in the available spec record.

MPN
LC2K09015FE7