Schneider Electric LC2K0910P72 — Contactors

TeSys K LC2K0910P72 reversing contactor, 3P, AC-3 9A, 230VAC

MPNLC2K0910P72
Obsolete

Schneider Electric TeSys K reversing contactor, LC2K0910P72, 3P, AC-3 ≤440 V 9 A, 1 NO, 230 V AC coil, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K0910P72 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LC2K0910P72 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-1 AC-3 AC-3e
LC2K0910P72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K0910P72 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K0910P72 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

It's a 3-pole unit rated AC-3 at 9 A up to 440 V, with a 230 V AC coil and one N.O. auxiliary contact.

The AC-3 rating of 9 A at 440 V is the motor-switching current — this contactor is sized for a 3-phase motor drawing up to 9 A under full-load starting conditions. AC-1 (resistive) and AC-4 (inching/plugging) ratings also apply, so it covers both simple on/off and reversing duty cycles. The 230 V AC coil draws from a control transformer or line voltage; verify coil suppression matches the PLC output if driven from a solid-state source. The 57 mm depth and 90 mm width fit standard DIN-rail enclosures, but the reversing busbar adds width — check fill factor against the gland plate before committing the panel layout.

Reversing contactors like this one are the standard building block for forward/reverse motor control in conveyors, hoists, pumps, and small machine tools. The preassembled reversing busbar saves panel wiring time compared to two separate contactors with an interlock kit.

Frequently asked questions

What are the key ratings for this reversing contactor?

It is a 3-pole reversing contactor rated AC-3 at 9 A up to 440 V, with a 230 V AC coil and one N.O. auxiliary contact. It also carries AC-1 and AC-4 utilisation categories for resistive and inching duty.

What is the physical size of the LC2K0910P72?

It measures 57 mm deep, 90 mm wide, and 58 mm high. The preassembled reversing busbar adds width beyond the base contactor footprint.

What approvals or compliance documentation does this part carry?

The contactor carries IP20 finger-safe protection per VDE 0106, V1 flame retardance per UL 94, and meets NF F 16-101/102 for railway fire-smoke-toxicity. Protective treatment conforms to IEC 60068 and DIN 50016 for corrosion resistance.

MPN