Skip to main content
Schneider Electric LC2K1201V7 — Contactors

Schneider TeSys K LC2K1201V7 reversing contactor, 3P AC-3 12

MPNLC2K1201V7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 12 A, 1 NC, 400 V AC coil, preassembled reversing busbar, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K1201V7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LC2K1201V7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-1 AC-4 AC-3
LC2K1201V7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1201V7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1201V7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric TeSys K LC2K1201V7 is a three-pole reversing contactor rated AC-3 at 12 A up to 440 V with a 400 V AC coil, preassembled with a reversing power busbar so it arrives ready to wire into a motor-reversing circuit. It carries one normally-closed auxiliary contact and is IP20 finger-safe per VDE 0106, suited for enclosed control panels where personnel access is restricted.

The AC-3 rating of 12 A at 440 V governs motor switching — this is the utilisation category for squirrel-cage motors during starting and plugging, so the contactor is sized for a motor drawing up to 12 A full-load current. The preassembled reversing busbar saves panel space and wiring time compared to building a reversing pair from two separate contactors plus a mechanical interlock.

Frequently asked questions

What is the closest pin-compatible alternative to LC2K1201V7 in this component family?

No official successor is listed in the available records. A parametric match within the TeSys K family would need the same pole count (3P), AC-3 current (12 A at 440 V), 400 V AC coil, and reversing configuration. Without a documented cross-reference, the safest path is to source the original order code against an RFQ.

What compliance documentation does this brand provide for LC2K1201V7?

The contactor carries a V1 flame-retardance rating per UL 94 and meets NF F 16-101/102 for railway fire behaviour. It is also protected against corrosive atmospheres per IEC 60068 and DIN 50016 (TC treatment).

MPN
LC2K1201V7