Skip to main content
Schneider Electric LC2K1210D7 — Contactors

LC2K1210D7 TeSys K Reversing Contactor, 12A AC-3, 42V Coil

MPNLC2K1210D7
Active

Schneider Electric TeSys K reversing contactor, LC2K1210D7, 3P, AC-3/AC-3e ≤440V 12A, 1NO auxiliary, 42V AC coil, IP20.

$125.50Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC2K1210D7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LC2K1210D7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-1 AC-4 AC-3 AC-3e
LC2K1210D7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1210D7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1210D7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The LC2K1210D7 is a reversing contactor from Schneider Electric's TeSys K series, preassembled with reversing power busbar for simplified panel wiring. It switches three-phase motor loads up to 12 A in AC-3 duty (≤440 V) and handles resistive loads under AC-1, plus AC-4 and AC-3e categories. The 42 V AC coil keeps control voltage separate from the power circuit, common in safety-isolated control schemes.

AC-3 at 12 A means this contactor is sized for starting and stopping squirrel-cage motors under full load — the standard duty cycle for conveyors, pumps, and fans. The AC-3e rating extends that to energy-efficient motors with higher inrush. The IP20 finger-safe enclosure (VDE 0106) suits it for enclosed panel mounting where operators won't contact live parts.

What it connects to

The 90 mm width means it occupies three 18 mm modular slots, typical for a reversing contactor with integrated busbar.

Frequently asked questions

What are the key ratings for this reversing contactor?

Rated 12 A in AC-3/AC-3e at ≤440 V, with a 42 V AC coil. It has three power poles (3 NO) and one NO auxiliary contact. The IP20 enclosure suits panel mounting.

What is the closest alternative to the LC2K1210D7 in the TeSys K family?

The LC2K1201D7 is the same reversing contactor but with a 1 NC auxiliary contact instead of 1 NO. For a non-reversing version, the LC1K1210D7 is the single-direction contactor with the same 12 A AC-3 rating and 42 V coil. Verify auxiliary contact configuration before substituting.

MPN
LC2K1210D7