Schneider Electric LC2K1210U7 — Contactors

Schneider TeSys K LC2K1210U7 Reversing Contactor, 3P, AC-3 1

MPNLC2K1210U7
Obsolete

Schneider Electric TeSys K reversing contactor, LC2K1210U7, 3P, AC-3 12A at 440V, 230-240VAC coil, preassembled with reversing busbar.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K1210U7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LC2K1210U7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4 AC-1
LC2K1210U7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1210U7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1210U7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

AC-3 at 12 A is the motor-switching rating — it's what governs the contactor's ability to make and break locked-rotor current. That 12 A at 440 V covers a 5.5 kW (7.5 HP) motor at 400 V three-phase. The AC-4 rating covers plugging and inching duty, which is lower; if you're reversing under load frequently, derate accordingly. The preassembled reversing busbar saves panel-build time — the mechanical interlock and power bus are already integrated, so you wire the line and load sides directly. The 57 mm depth and 90 mm width mean it fits standard 45 mm DIN-rail spacing with room for adjacent devices. Operating altitude is 2000 m without derating. Above that, you'll need to account for reduced air density on the arc extinction and thermal dissipation.

Frequently asked questions

Is the LC2K1210U7 obsolete?

Yes, it's officially obsolete. No direct manufacturer successor is listed. Sourcing is through surplus or broker channels — quoted to order against an RFQ.

What are the key ratings for the LC2K1210U7?

Three-pole reversing contactor, AC-3 rated 12 A at 440 V, coil 230-240 V AC. Preassembled with reversing busbar. IP20 finger-safe, flame retardance V1 per UL 94 and NF F 16-101/102 compliant.

What is the depth of the LC2K1210U7?

57 mm depth, 90 mm width, 58 mm height. Fits standard 45 mm DIN-rail spacing.

What compliance documentation is available for the LC2K1210U7?

The part carries V1 flame retardance per UL 94, IP20 per VDE 0106, and railway fire-smoke-toxicity compliance per NF F 16-101 and NF F 16-102. It also meets IEC 60068 for shock and vibration and IEC 60068 for protective treatment (TC). The manufacturer's standard declarations (CE, UKCA, RoHS) apply to the TeSys K range.

MPN