Schneider Electric TeSys K reversing contactor, LC2K1601P7, 3P, AC-3 ≤440 V 16 A, 1 NC, 230 V AC coil, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC2K1601P7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K1601P7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3
LC2K1601P7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1601P7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1601P7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The LC2K1601P7 is a TeSys K reversing contactor from Schneider Electric — a 3-pole, 3 NO power pole unit rated for AC-3 duty at 16 A up to 440 V, with a 230 V AC coil and one NC auxiliary contact. It ships preassembled with the reversing power busbar, so you don't need to source the mechanical interlock and busbar kit separately; it's ready to drop into a panel for forward-reverse motor control of a three-phase induction motor.

The AC-3 rating of 16 A at ≤440 V governs motor switching — that's the rating that matters for a standard squirrel-cage motor start/stop duty. Mechanical robustness is specified: the contactor withstands 10 Gn shocks on Y and Z axes (closed) and 4 Gn vibration at 5-300 Hz when closed, per IEC 60068-2-27 and IEC 60068-2-6. That's enough for most conveyor and pump applications, but if you're mounting it on a high-vibration press or mobile equipment, check the open-contactor limits (2 Gn vibration, 6-10 Gn shock) — the part is less tolerant when de-energized.

Where this class of part is used

Reversing contactors of this size (16 A AC-3) are used in motor control panels for small three-phase motors driving conveyors, hoists, door operators, and pump sets that need forward-reverse operation. The pre-assembled reversing busbar saves panel wiring time and reduces the chance of interlock wiring errors during commissioning.

Frequently asked questions

What are the key ratings I need to match for a replacement?

The critical specs are: 3-pole reversing contactor, AC-3 rating of 16 A at ≤440 V, 230 V AC coil, one NC auxiliary contact, and pre-assembled with reversing power busbar. Any replacement candidate must match these ratings and the physical footprint (57 mm depth, 90 mm width, 58 mm height) to fit the same panel layout.

What compliance documentation is available for this part?

The part carries UL 94 V1 flame retardance rating on the insulation, and conforms to NF F 16-101 and NF F 16-102 for railway fire behavior. The protective treatment conforms to IEC 60068 and DIN 50016. Standard Schneider Electric declarations for RoHS and REACH would apply to this production era.