Skip to main content
Schneider Electric LC2K16105J7 — Contactors

Schneider TeSys K LC2K16105J7 reversing contactor, 3P, 16 A

MPNLC2K16105J7
Active

Schneider Electric TeSys K reversing contactor, LC2K16105J7, 3P, AC-3 <=440 V 16 A, 1 NO, 12 V AC coil, IP20, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC2K16105J7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K16105J7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4
LC2K16105J7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K16105J7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K16105J7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

That 16 A AC-3 figure is what governs motor switching — it's the current the contactor can handle when making and breaking motor inrush. The 3-pole NO power pole composition matches standard three-phase reversing duty.

The contactor measures 90 mm wide by 58 mm high by 57 mm deep, with IP20 finger-safe protection per VDE 0106. Operating temperature range is -25 to 50 °C, with storage from -50 to 80 °C, and it runs without derating up to 2000 m altitude — fine for most plant-floor and outdoor cabinet installations. Mechanical robustness is specified: the contactor withstands 10 Gn shocks on Y and Z axes (closed) and 15 Gn on Y and Z axes (closed) per IEC 60068-2-27, plus 4 Gn vibration closed across 5-300 Hz. That's enough for most industrial machinery and conveyor lines.

Flame retardance meets V1 per UL 94, plus NF F 16-101 and NF F 16-102 for rail applications. Protective treatment conforms to IEC 60068 and DIN 50016 for environmental resistance. The IP20 rating provides basic finger protection for panel installation.

Frequently asked questions

What are the key ratings for this reversing contactor?

AC-3 rating is 16 A at up to 440 V AC, with a 12 V AC coil. It's a 3-pole reversing contactor preassembled with a reversing power busbar. The contactor is rated for AC-4 duty as well, covering inching and plugging applications.

What is the physical size of LC2K16105J7?

Width 90 mm, height 58 mm, depth 57 mm. The 57 mm depth is the key dimension for enclosure fit — it's shallow enough for most standard cabinets.

What compliance certifications does this part carry?

Flame retardance V1 per UL 94, plus NF F 16-101 and NF F 16-102 for rail rolling stock. Protective treatment per IEC 60068 and DIN 50016. IP20 finger protection per VDE 0106.

MPN
LC2K16105J7