Skip to main content
Schneider Electric LC3D090AF7 — Contactors

Schneider TeSys LC3D090AF7 Star Delta Starter, 9 A, 110 V AC

MPNLC3D090AF7
Obsolete

Schneider Electric TeSys D, star delta starter, 3 x 3P (3 NO), 9 A, 110 V AC coil, IP20 front face.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC3D090AF7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3D090AF7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3
LC3D090AF7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3D090AF7 — Environmental
ParameterValue
IP degree of protectionIP20 front face conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms
Protective treatment / pollution degreeTH conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94

Product details

It switches motor loads in AC-3 duty, rated at 9 A, with a 110 V AC coil.

The 110 V AC coil means it's intended for control circuits fed from a 110 V AC supply — common in North American panel designs. The 3 x 3P (3 NO) power pole configuration provides three normally open poles per contactor, which is the standard arrangement for star-delta transition. Operating altitude of 3000 m without derating covers most installations; above that, the switching capacity must be reduced.

Vibration resistance of 4 Gn (closed contacts) and shock resistance of 15 Gn (closed) make it suitable for installations near rotating machinery or on mobile equipment. Climatic withstand conforms to IACS and IEC 60947-1 Annex Q category D, covering humid and salt-laden atmospheres.

Frequently asked questions

What is the closest replacement for the LC3D090AF7?

No official successor order code is recorded in the lifecycle data. To find a current-production equivalent, verify the coil voltage (110 V AC), current rating (9 A AC-3), and star-delta configuration against the current TeSys D catalog.

What are the key specifications of the LC3D090AF7?

It is a TeSys D star delta starter with 3 x 3P (3 NO) contacts, rated 9 A in AC-3 motor switching duty, with a 110 V AC coil. The front face is IP20 rated.

What compliance documentation is available for this part?

The part carries fire resistance to 850 °C per IEC 60695-2-1, UL 94 V1 flame retardance, and climatic withstand per IACS and IEC 60947-1 Annex Q category D. It is rated for pollution degree 3.

MPN