Skip to main content
Schneider Electric LC3D090AV7 — Contactors

Schneider LC3D090AV7 TeSys D Star Delta Starter, 9 A, 400 V

MPNLC3D090AV7
Obsolete

Schneider Electric TeSys D, star delta starter, 3 x 3P (3 NO), 9 A, 400 V AC coil.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC3D090AV7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3D090AV7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3
LC3D090AV7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3D090AV7 — Environmental
ParameterValue
IP degree of protectionIP20 front face conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms
Protective treatment / pollution degreeTH conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94

Product details

The LC3D090AV7 is a TeSys D star delta starter from Schneider Electric, designed for motor control in AC-3 duty. It switches 9 A at the coil voltage of 400 V AC, with three normally open power poles per phase (3 x 3P).

Schneider has marked the LC3D090AV7 as Obsolete. There is no official successor order code listed, so the only sourcing channel is the surplus and broker market. We can source it to order against an RFQ.

Rated for AC-3 utilization category, meaning it's built for switching squirrel-cage motors under normal starting and running conditions — not resistive loads. The 9 A rating is the AC-3 motor current; for a 400 V supply this typically covers motors up to about 4 kW, but always verify against your motor's full-load current.

Mechanical and environmental robustness

Withstands vibration up to 4 Gn when closed (2 Gn open) and shocks up to 15 Gn closed — typical for machine-mounted contactors near conveyors or compressors. Climatic withstand conforms to IACS and IEC 60947-1 Annex Q Category D, plus TH protective treatment per IEC 60068-2-30 for damp heat. Fire resistance to 850 °C (IEC 60695-2-1) and V1 flame retardance (UL 94).

Frequently asked questions

What is the closest alternative to the LC3D090AV7?

There is no official successor order code listed. A functionally similar TeSys D star delta starter with the same coil voltage and current rating would need to be selected from current catalog — contact us with your application details for a cross-reference.

What are the key ratings of the LC3D090AV7?

It is a 9 A star delta starter, 400 V AC coil, 3 x 3P NO contacts, AC-3 utilization category, IP20 front face, operating temperature -40 to 70 °C, pollution degree 3.

MPN
LC3D090AV7