Skip to main content
Schneider Electric LC3D09AQ7 — Contactors

Schneider LC3D09AQ7 TeSys D Star Delta Starter, 9 A, 380 V A

MPNLC3D09AQ7
Obsolete

Schneider TeSys D star delta starter, LC3D09AQ7, 3 x 3P (3 NO), 9 A, 380 V AC coil, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC3D09AQ7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3D09AQ7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3
LC3D09AQ7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3D09AQ7 — Environmental
ParameterValue
IP degree of protectionIP20 front face conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms
Protective treatment / pollution degreeTH conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94

Product details

The LC3D09AQ7 is a Schneider TeSys D star delta starter — a pre-wired assembly that combines three contactors in a single unit for reduced-voltage starting of three-phase induction motors. It is configured as 3 x 3P (3 NO) and rated for AC-3 utilisation category at 9 A, with a 380 V AC coil.

The AC-3 rating of 9 A means this starter is sized for switching three-phase motors up to that current during starting and plugging — the duty that governs contactor life in motor control. The 380 V AC coil matches standard European control voltages; verify your panel's control transformer output before committing the BOM line. IP20 front-face protection (IEC 60529) means the front of the unit is finger-safe, but the terminals are not protected against water ingress — mount inside a rated enclosure. Flame retardance V1 per UL 94 and fire resistance to 850 °C per IEC 60695-2-1 mean the housing will not propagate a flame or sustain combustion — important for panel-level safety compliance.

Deployment context

As a pre-wired star delta starter, the LC3D09AQ7 mounts directly into the panel — typically on a DIN rail or backplate — and connects to the motor contactor group without additional inter-wiring.

Frequently asked questions

What is the closest alternative to the LC3D09AQ7?

No official successor is listed in the record. For a direct replacement, you would need to source the original part through surplus or broker channels, or work with a Schneider distributor to identify a current TeSys D star delta starter with equivalent ratings.

What are the key ratings of the LC3D09AQ7?

It is a 9 A AC-3 star delta starter with a 380 V AC coil, 3 x 3P (3 NO) configuration, IP20 front face, pollution degree 3, and V1 flame retardance.

MPN