Schneider LC3D09AV7 TeSys D Star Delta Starter, 9 A, 400 V A

MPNLC3D09AV7
Obsolete

Schneider Electric TeSys D star delta starter, LC3D09AV7, 3 x 3P (3 NO), 9 A, 400 V AC coil, AC-3 utilisation category.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC3D09AV7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3D09AV7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3
LC3D09AV7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3D09AV7 — Environmental
ParameterValue
IP degree of protectionIP20 front face conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms
Protective treatment / pollution degreeTH conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94

Product details

It carries three power poles (3 x 3P, all NO) rated for AC-3 motor control at 9 A, with a 400 V AC coil. AC-3 utilisation category means this starter is sized for starting squirrel-cage motors and disconnecting them while running — the 9 A rating governs the motor FLC it can handle, not a resistive load. The IP20 front face keeps fingers out of the live terminals inside the enclosure.

Rated for pollution degree 3 (industrial environment, conductive pollution), the LC3D09AV7 operates from -40 to 70 °C ambient and stores from -60 to 80 °C. It derates above 3000 m altitude — no derating needed below that. Climatic withstand conforms to IACS and IEC 60947-1 Annex Q category D, with TH protective treatment per IEC 60068-2-30 for humid conditions. Fire resistance at 850 °C (IEC 60695-2-1) and V1 flame retardance (UL 94) mean the housing won't propagate a flame — relevant for panel builders who need to pass a cabinet-level fire test. Vibration withstand: 2 Gn contactor open, 4 Gn closed over 5–300 Hz; shock: 10 Gn open, 15 Gn closed for 11 ms.

Because this is a pre-wired star delta starter, a direct replacement requires matching the 9 A AC-3 rating, 400 V AC coil voltage, and the 3 x 3P contact configuration. A panel OEM or site electrical engineer should verify the mounting footprint and wiring scheme against the existing assembly before committing a substitute.

Frequently asked questions

What is the LC3D09AV7's range and product name?

It belongs to the TeSys range, specifically the TeSys D family of motor control components.

What are the key ratings for this star delta starter?

Rated 9 A in AC-3 utilisation category for motor control, with a 400 V AC coil. It has 3 x 3P (3 NO) power poles, IP20 front face protection, and operates from -40 to 70 °C ambient.

What compliance documentation does this part carry?

The LC3D09AV7 meets fire resistance at 850 °C (IEC 60695-2-1), V1 flame retardance (UL 94), pollution degree 3, and climatic withstand per IACS and IEC 60947-1 Annex Q category D. It also carries TH protective treatment per IEC 60068-2-30.