Schneider LC3D120AM7 TeSys D Star Delta Starter, 12A, 220V A

MPNLC3D120AM7
Obsolete

Schneider TeSys D star delta starter, 3 x 3P (3 NO), 12 A, 220 V AC coil, AC-3 motor control duty, IP20 front face.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC3D120AM7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3D120AM7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3
LC3D120AM7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3D120AM7 — Environmental
ParameterValue
IP degree of protectionIP20 front face conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms
Protective treatment / pollution degreeTH conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94

Product details

The LC3D120AM7 is a TeSys D star delta starter from Schneider, built as a pre-wired assembly with three power poles, each carrying 3 NO contacts. It's rated for 12 A in AC-3 utilisation category, which means it's designed to switch three-phase induction motors during start-up — the star-delta transition limits inrush current, then the contactor set handles full-load running. The 220 V AC coil matches standard control voltages across European and Asian panel designs.

The 12 A AC-3 rating governs motor duty, not resistive loads. AC-3 covers starting and switching off squirrel-cage motors under load. Pollution degree 3 confirms it's intended for industrial atmospheres with conductive pollution, so no extra conformal coating is needed in most cabinet environments. Fire resistance to 850 °C (IEC 60695-2-1) and V1 flame retardance (UL 94) mean the plastic housing won't propagate a flame if a fault arc or external fire hits the panel — important for UL-listed assemblies and machinery CE marking.

Where this class of part is used

Star delta starters like this one are the standard way to start three-phase induction motors above about 5 kW where direct-on-line starting would cause voltage dips or mechanical shock. The pre-wired assembly saves panel-build time — you get the three contactors, the timing relay, and the interconnections in one package that clips onto a DIN rail. Typical applications include pumps, compressors, conveyors, and fans where the load doesn't require a soft starter or VFD.

Frequently asked questions

What are the key ratings I need to match for a replacement?

The critical specs are 12 A at AC-3 utilisation category for motor switching, 220 V AC coil voltage, and the 3 x 3P (3 NO) contact configuration for star-delta starting. The IP20 front face and pollution degree 3 are standard for panel-mount gear.

MPN
LC3D120AM7