Skip to main content
Schneider Electric LC3D12AE7 — Contactors

Schneider LC3D12AE7 TeSys D Star Delta Starter, 12 A, 48 V A

MPNLC3D12AE7
Obsolete

Schneider Electric TeSys D series, star delta starter, order code LC3D12AE7, 12 A, 48 V AC coil, 3 x 3P (3 NO) poles.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC3D12AE7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3D12AE7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3
LC3D12AE7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3D12AE7 — Environmental
ParameterValue
IP degree of protectionIP20 front face conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms
Protective treatment / pollution degreeTH conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94

Product details

It carries a 12 A rating in AC-3 utilisation category, meaning it is sized for switching three-phase induction motors during start-up transition — the star-to-delta changeover that limits inrush current on the line. The contact configuration is 3 x 3P (3 NO), giving three normally-open power poles per phase for the star and delta contactors plus the line contactor. The coil is 48 V AC, which is common in control circuits fed from a 48 V control transformer.

Sourcing reality — obsolete part

If your application requires a current-production star delta starter in the TeSys D family, a parametric cross-reference to a similar-rated unit with a 48 V AC coil would need to be validated against the existing panel wiring and mounting footprint.

Environmental and compliance ratings

Climatic withstand conforms to IACS and IEC 60947-1 Annex Q category D, and the protective treatment is TH per IEC 60068-2-30 for damp heat. Altitude rating is 3000 m without derating.

Mechanical robustness for motor starting duty

Vibration resistance is 2 Gn with contactor open and 4 Gn with contactor closed across 5–300 Hz. Shock resistance is 10 Gn for 11 ms with contactor open, 15 Gn for 11 ms closed.

Frequently asked questions

What is the closest replacement for the LC3D12AE7?

No official successor order code is recorded in the lifecycle documentation. A current-production TeSys D star delta starter with matching 12 A AC-3 rating and 48 V AC coil would need to be identified and validated for fit against the existing panel layout.

What are the key ratings of the LC3D12AE7?

It is a 12 A star delta starter in AC-3 utilisation category, with a 48 V AC coil, 3 x 3P (3 NO) power pole configuration, IP20 front face protection, and operating temperature range of -40 to 70 °C.

What compliance standards does the LC3D12AE7 meet?

It meets IEC 60695-2-1 fire resistance at 850 °C, UL 94 V1 flame retardance, IEC 60947-1 Annex Q category D climatic withstand, IACS, and IEC 60068-2-30 TH protective treatment. Pollution degree is 3.

MPN
LC3D12AE7