Skip to main content
Schneider Electric LC3D12AF7 — Contactors

TeSys LC3D12AF7 Star Delta Starter, 12 A, 110 V AC Coil

MPNLC3D12AF7
Obsolete

TeSys D, star delta starter, 3 x 3P (3 NO), 12 A, 110 V AC coil.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC3D12AF7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3D12AF7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3
LC3D12AF7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3D12AF7 — Environmental
ParameterValue
IP degree of protectionIP20 front face conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms
Protective treatment / pollution degreeTH conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94

Product details

The LC3D12AF7 is a TeSys D star delta starter from Schneider Electric, pre-wired for reduced-voltage starting of three-phase motors. It carries 3 x 3P (3 NO) power poles rated 12 A in AC-3 utilisation category, meaning it handles motor switching up to that current under full-load starts. The 110 V AC coil is built into the assembly, so no separate contactor coil selection is needed — it's a matched set for a standard star-delta transition.

Designed for panel mounting, the IP20 front face protects against finger contact during commissioning. The pre-wired format saves panel build time: terminals are already connected between the main and delta contactors inside the unit.

For a 400 V three-phase motor, that typically covers a 5.5 kW induction motor — the standard rule of thumb for star-delta starters. The 110 V AC coil means the control transformer or PLC output must supply 110 V AC; verify your control voltage matches before wiring. The unit operates from -40 to 70 °C at rated coil voltage, so it handles warm cabinets without derating, and stores down to -60 °C.

Environmental and mechanical tolerance

Rated for 3000 m altitude without derating — fine for most installations outside high-mountain sites. Vibration resistance: 2 Gn contactor open, 4 Gn closed over 5-300 Hz. Shock: 10 Gn open, 15 Gn closed for 11 ms. TH protective treatment per IEC 60068-2-30 means it withstands damp heat cycling, common in non-conditioned plant floors.

Frequently asked questions

What is the closest alternative to LC3D12AF7?

No official successor order code is provided in the lifecycle record. A parametric substitute would need to match the 12 A AC-3 rating, 3 x 3P (3 NO) configuration, 110 V AC coil, and star-delta pre-wired format. Consult a sourcing specialist to cross-reference against current TeSys D or TeSys Deca star-delta starters.

What range and product name does LC3D12AF7 belong to?

It belongs to the TeSys range, specifically the TeSys D product name.

What compliance documentation is available for LC3D12AF7?

The part carries fire resistance at 850 °C conforming to IEC 60695-2-1, flame retardance V1 conforming to UL 94, climatic withstand conforming to IACS and IEC 60947-1 Annex Q category D, and TH protective treatment conforming to IEC 60068-2-30. Standard RoHS and REACH declarations would be available from the manufacturer's documentation archive for this series.

MPN
LC3D12AF7