Schneider Electric LC3D12AM7 — Contactors

Schneider LC3D12AM7 TeSys D Star Delta Starter, 12 A, 220 V

MPNLC3D12AM7
Active

Schneider Electric TeSys D, star delta starter, 3 x 3P (3 NO), 12 A, 220 V AC coil, IP20 front face.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC3D12AM7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3D12AM7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3
LC3D12AM7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3D12AM7 — Environmental
ParameterValue
IP degree of protectionIP20 front face conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms
Protective treatment / pollution degreeTH conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94

Product details

The LC3D12AM7 is a pre-wired star delta starter from the TeSys D range, built for motor control in AC-3 duty. It carries three power poles, each with 3 NO contacts, rated at 12 A. The coil pulls in on 220 V AC. This is the packaged starter assembly — contactors already interconnected for star-delta transition — so it saves panel wiring time on a standard motor start scheme.

AC-3 category means it is rated for starting squirrel-cage motors and switching them off while running — the 12 A rating governs the motor full-load current it can handle, not the inrush. For a typical 400 V three-phase motor, 12 A AC-3 corresponds roughly to a 5.5 kW load; confirm the motor FLC against the starter rating before committing the BOM line. The IP20 front face means the terminals are finger-safe when mounted in an enclosure, but the starter itself is not sealed against dust or moisture — it needs to live inside a panel or a weatherproof cabinet. Fire resistance to 850 °C per IEC 60695-2-1 and V-0 flame retardance per UL 94 mean the housing materials meet the thermal runaway standards for enclosed power equipment — important for panel certification to IEC 60947 or UL 508A.

Frequently asked questions

What is the closest alternative to LC3D12AM7 in the TeSys D family?

The TeSys D range includes star delta starters with different coil voltages and current ratings. The LC3D12AM7 is the 12 A variant with a 220 V AC coil. A higher-current sibling (e.g., LC3D18AM7) shares the same form factor and coil voltage but steps up to 18 A for larger motors. The choice between them is driven by the motor FLC, not by wiring or panel layout.

What compliance documentation does Schneider provide for this part?

The part carries fire resistance to 850 °C (IEC 60695-2-1), V-1 flame retardance (UL 94), pollution degree 3, and climatic withstand per IACS and IEC 60947-1 Annex Q category D. Protective treatment is TH per IEC 60068-2-30. These are the documented compliance markers; full RoHS/REACH declarations are typically available from Schneider's product documentation portal.