Skip to main content
Schneider Electric LC4D09AM7 — Motor Starters

Schneider LC4D09AM7 TeSys DOL Starter, 9 A, 220 V AC Coil

MPNLC4D09AM7
Active

Schneider Electric TeSys LC4-D DOL starter, 9 A rated operational current, 220 V AC 50/60 Hz coil, AC-3 utilisation category, on mounting plate.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC4D09AM7 — Mechanical & Connection
ParameterValue
Width86 mm
Height173 mm
Depth98 mm
LC4D09AM7 — Other specifications
ParameterValue
Motor power4 kW at 380...400 V AC 50/60 Hz 4 kW at 415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 2.2 kW at 220...230 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz
Mounting supportPlate
Range of productTeSys
Device short nameLC4
Device compositionContactor Fuse disconnector
Utilisation categoryAC-3
Product or component typeDOL starter
[Ie] rated operational current9 A
[Ue] rated operational voltage220 V AC 50/60 Hz

Product details

Its AC-3 rating means it is designed for starting and stopping squirrel-cage induction motors under load — the standard duty for most pump, fan, and conveyor applications in industrial control panels. At 380…400 V AC supply, the unit handles motor loads up to 4 kW, which matches the most common small-motor range in European and Asian 400 V distribution systems.

The starter ships on a plate (173 mm high × 86 mm wide × 98 mm deep) for direct bolting to a back panel or subplate — no DIN rail required. The plate footprint keeps the contactor and fuse disconnector aligned as a single assembly, simplifying panel layout and wiring compared to building the same circuit from separate components.

Frequently asked questions

Is LC4D09AM7 suitable for a 4 kW motor?

Yes, the LC4D09AM7 is rated for 4 kW motor loads at 380…400 V AC, 4 kW at 415 V AC, and 4 kW at 440 V AC, all at 50/60 Hz. It also covers 2.2 kW at 220…230 V AC and 5.5 kW at 500 V AC.

Does LC4D09AM7 come with a mounting plate?

Yes, the DOL starter is supplied on a mounting plate for direct panel installation.

What is the difference between a DOL starter and a soft starter?

A DOL starter applies full line voltage directly to the motor on start, producing high inrush current and torque. A soft starter ramps voltage up gradually to limit inrush and mechanical stress. The LC4D09AM7 is a DOL starter, suited for applications where the motor and load can tolerate a direct start.

Can I use LC4D09AM7 for a 3-phase motor?

Yes, the LC4D09AM7 is designed for three-phase motor switching under AC-3 duty; the 4 kW rating at 380…400 V AC corresponds to a standard three-phase induction motor.

MPN
LC4D09AM7