It delivers motor power up to 11 kW at 220 V AC, 22 kW at 380/400 V AC, and 26 kW at 415/440 V AC (50/60 Hz), which covers common European and North American line voltages for a standard-duty motor starter.
Enclosure and deployment context
Housed in a polycarbonate enclosure rated IP65 per IEC 60529, the LE3D35M7 withstands washdown and dust ingress — suitable for standalone mounting on a machine frame or wall in food-and-bev, packaging, or light industrial lines. Impact protection is IK07 per IEC 60529, so the enclosure resists mechanical shock from tools or debris in a production environment. Cable entries include multiple ISO20, ISO25, ISO32, and ISO40 knockouts on both top and bottom faces, giving flexibility for conduit or gland routing during installation.
The LE3D35M7 is listed as Obsolete per the manufacturer's lifecycle record. For a BOM line that must be filled, this part is sourced through surplus or broker channels against an RFQ — the buyer should confirm fit with the existing enclosure cutouts and control voltage before committing.
The 35 A AC-3 rating governs motor switching: it handles the inrush during star-delta transition and the running current in delta configuration, so it fits a motor drawing up to 35 A under load. The device composition requires a separately ordered thermal overload relay and a mechanical interlock for the star-delta contactors — the enclosure does not include these, so the BOM must account for them.