Schneider Electric LE4D18P7A05 — Overload Relays

Schneider TeSys LE LE4D18P7A05 Enclosed DOL Starter, 18A, 23

MPNLE4D18P7A05
Obsolete

Schneider Electric TeSys LE enclosed DOL starter, 18 A conventional free-air thermal current, 230 V AC 50/60 Hz coil, push-button reset, IP65, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LE4D18P7A05 — Mechanical
ParameterValue
Width186 mm
Height330 mm
Depth175.5 mm

Product details

The LE4D18P7A05 is a Schneider Electric TeSys LE enclosed direct-on-line (DOL) starter, rated for 18 A conventional free-air thermal current (Ith) and a 230 V AC 50/60 Hz control coil. It's a self-contained unit — contactor, overload relay (ordered separately), and fuse disconnector in a polycarbonate IP65 enclosure — ready to bolt onto a machine or wall, not a panel-mount component. It's designed for standard AC-3 duty (starting and stopping squirrel-cage motors), so the 18 A thermal current translates to real motor loads: 10 kW at 500 V AC, 9 kW at 415/440 V AC, 7.5 kW at 380/400 V AC, or 4 kW at 220/230 V AC. The push-button reset (blue R) means an operator can clear a trip locally without opening the enclosure.

IP65 and IK07 protection (conforming to IEC 60529) lets this starter live on the machine frame in washdown areas, dusty environments, or outdoors under a canopy — not just inside a clean control panel. The polycarbonate enclosure resists corrosion, and the cable entries (ISO20/25/32/40 top and bottom) give flexibility for routing conduit or gland in the field. Compliance with IEC 60947-4-1 covers the coordination requirements for motor starters — the associated fuse rating of 20 A aM (10x38 mm) is the factory-recommended short-circuit protection to keep the starter in the Type 2 coordination zone.

Sourcing decision

If you're freezing a BOM or chasing a line-down replacement, the first question is whether you can accept a current-series alternative (TeSys Deca) with a possible re-drill or adapter plate. If not, we can quote the LE4D18P7A05 from our surplus network — lead time depends on what's in the channel, so send the RFQ with your target date and quantity.

Frequently asked questions

What are the key ratings I need for a replacement?

18 A conventional free-air thermal current (Ith), AC-3 utilization category, 230 V AC 50/60 Hz coil, IP65 enclosure. Motor power depends on supply voltage — 7.5 kW at 380/400 V, 9 kW at 415/440 V, 10 kW at 500 V.

What compliance standards does this starter meet?

IEC 60947-4-1 for motor starters. IP65 and IK07 per IEC 60529. The associated fuse recommendation is 20 A aM (10x38 mm).