The Schneider Electric LE4K065M7 is an enclosed direct-on-line (DOL) starter from the TeSys LE range, rated for a conventional free-air thermal current of 6 A and a 220 V AC 50/60 Hz control coil. It is designed to start and stop three-phase induction motors in a standard environment, with motor power ratings of 3 kW at 440 V AC, 2.2 kW at 380/400 V or 415 V AC, and 1.5 kW at 220/230 V AC. The IP65 polycarbonate enclosure (IK09 impact-rated) makes it suitable for washdown or dusty environments — think food processing lines, packaging cells, or outdoor-adjacent installations — without needing a separate panel.
For motor duty, the actual operating current is determined by the motor full-load amps, which must be below this figure after accounting for the thermal overload relay (ordered separately). The associated fuse rating is 10 A aM in a 10 x 38 mm cartridge. This is the maximum short-circuit protection the starter is coordinated with. The control circuit runs on 220 V AC 50/60 Hz. If your panel control voltage is different, you will need an interface relay or a different starter variant. Enclosure dimensions are 175 mm wide, 165 mm high, 146 mm deep — compact enough for machine-mounted or wall-mounted installation. Cable entries include multiple ISO20 knockouts plus Pg 13 and Pg 16 ports top and bottom.