Skip to main content
Schneider Electric LG1K065M705 — Motor Starters

Schneider LG1K065M705 TeSys LG Enclosed DOL Starter

MPNLG1K065M705
Active

Schneider Electric TeSys LG enclosed DOL starter, LG1K065M705, 0.63-1 A thermal protection range, 220/230 V AC coil, IP55, AC-3 utilisation category.

$295.08Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LG1K065M705 — Mechanical & Connection
ParameterValue
Width175 mm
Height165 mm
Depth165 mm

Product details

The Schneider Electric TeSys LG1K065M705 is an enclosed direct-on-line starter that combines a contactor, a circuit-breaker, and a switch disconnector in one IP55 polycarbonate enclosure — a right-sized spec for a single motor branch that needs local isolation and overload protection without a separate panel build. Rated for AC-3 utilisation category, it is built for starting squirrel-cage motors and switching them off only after they are up to speed — the duty that governs real motor starts, not resistive loads. The thermal protection adjustment range of 0.63...1 A sets the overload relay trip window; for a 0.12 kW motor at 230 V or a 0.25 kW motor at 400/415 V, this is the range that keeps the winding protected without nuisance tripping. Verify your control transformer taps before wiring.

Deployment context

Cable entries are pre-punched: four knockouts on top and four on bottom, each accepting Pg 13 or Pg 16 glands, so you can land motor and supply cables without drilling the enclosure. The front panel carries a white start pushbutton, a black stop pushbutton, and a red rotary emergency-stop handle — the operator interface is built in, so no separate control station is needed for local start/stop and emergency isolation.

It is a standard catalogue item in the TeSys LG family, so the BOM line is stable for new designs and spares inventory alike.

Frequently asked questions

What is the amperage range of LG1K065M705?

The thermal protection adjustment range is 0.63 to 1 A, which sets the overload relay trip point for the connected motor.

Does LG1K065M705 include a circuit breaker?

Yes, the enclosed DOL starter integrates a circuit-breaker, a contactor, and a switch disconnector in one unit, along with the thermal overload relay.

What is the difference between LG1K065M705 and LG1K065M706?

The two order codes differ only in the control circuit voltage: LG1K065M705 uses a 220/230 V AC coil, while LG1K065M706 uses a different coil voltage. All other ratings — enclosure, thermal range, motor power, IP rating — are identical.

Where can I buy LG1K065M705?

This part is sourced to order; availability and pricing are confirmed at quote time.

MPN
LG1K065M705