Schneider Electric LG1K065N707 — Motor Starters

TeSys LG1K065N707 Enclosed DOL Starter, 1.6-2.5 A, Obsolete

MPNLG1K065N707
Obsolete

Schneider Electric TeSys LG series, LG1K065N707, enclosed DOL starter, 1.6...2.5 A thermal protection, 400/415 V AC coil, IP55, polycarbonate enclosure.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LG1K065N707 — Mechanical & Connection
ParameterValue
Width175 mm
Height165 mm
Depth165 mm

Product details

The Schneider Electric TeSys LG1K065N707 is an enclosed direct-on-line (DOL) starter combining a contactor, switch disconnector, and circuit-breaker in a single IP55 polycarbonate enclosure — a self-contained motor start-and-protect package for standard-environment industrial lines. Rated for AC-3 duty, it handles a 0.37 kW motor at 220/230 V AC, 0.75 kW at 400/415 V AC, and 1.1 kW at 440 V AC, all at 50/60 Hz. The thermal protection adjustment range of 1.6...2.5 A lets it match small three-phase induction motors — think pumps, fans, or small conveyors — and the IP55 enclosure means it can sit on the machine frame or near the line, not just in a sealed panel.

This part is obsolete per Schneider's lifecycle status, so it is no longer in active factory production. If you are qualifying a form-fit-function replacement, the deciding specs to match are the 1.6...2.5 A thermal adjustment range, the 400/415 V AC coil voltage, the AC-3 utilization category, and the IP55 polycarbonate enclosure — any substitute must hold those same ratings to drop in without a panel rework.

The enclosure carries four cable entries — two Pg 13 and two Pg 16 at both top and bottom — which gives enough room for the incoming mains and the motor leads plus a control loop. At 165 mm deep, 175 mm wide, and 165 mm tall, the polycarbonate box fits a standard machine-mount footprint. The IK07 impact rating means it withstands the occasional tool bump on the line floor, and compliance with IEC 60204-1 (machinery safety) and IEC 60947-4-1 (contactors and motor-starters) covers the electrical safety documentation for a CE-declared machine.

Frequently asked questions

Is LG1K065N707 obsolete?

Yes, LG1K065N707 is obsolete per Schneider Electric's lifecycle status. It is no longer in active factory production and must be sourced through surplus or independent distribution channels.

What is the replacement for LG1K065N707?

No official successor order code is listed in the lifecycle record for LG1K065N707. A form-fit-function replacement must match the 1.6...2.5 A thermal adjustment range, the 400/415 V AC coil, AC-3 duty rating, and IP55 polycarbonate enclosure.

What is the difference between TeSys LG and TeSys GV?

TeSys LG is an enclosed DOL starter — a self-contained unit with contactor, switch disconnector, and circuit-breaker in an IP55 box, ready for direct machine mounting. TeSys GV refers to Schneider's manual motor starters and disconnect switches, typically panel-mounted or DIN-rail components that are part of a larger starter assembly rather than a complete enclosed starter.

MPN