Skip to main content
Schneider Electric LG1K065Q705 — Motor Starters

Schneider TeSys LG1K065Q705 Enclosed DOL Starter, 0.63-1A

MPNLG1K065Q705
Obsolete

Schneider Electric TeSys LG enclosed DOL starter, 0.63-1 A thermal protection, 380/400 V AC coil, IP55, polycarbonate enclosure.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LG1K065Q705 — Mechanical & Connection
ParameterValue
Width175 mm
Height165 mm
Depth165 mm

Product details

The Schneider Electric TeSys LG1K065Q705 is an enclosed direct-on-line (DOL) starter in the TeSys LG range, combining a contactor, a circuit-breaker, and a switch disconnector in a single IP55 polycarbonate enclosure. It is rated for AC-3 utilisation category and delivers 0.12 kW at 220/230 V AC and 0.25 kW at 400/415 V AC or 440 V AC, 50/60 Hz. The thermal protection adjustment range spans 0.63 to 1 A, and the control circuit voltage is 380/400 V AC. The unit includes a white push-button start, a black push-button stop, and a red rotary handle emergency stop. It meets IEC 60204-1 and IEC 60947-4-1 standards, with IP55 protection against dust and water jets and IK07 impact resistance. The polycarbonate enclosure has four cable entries: two Pg 13 and two Pg 16 at both top and bottom.

The LG1K065Q705 is obsolete. A current-production TeSys LG or TeSys GV enclosed starter with 0.63–1 A thermal range and 380/400 V AC coil is the closest functional equivalent. Verify the form factor and cable entry layout against your existing panel cutout before committing.

The 0.63–1 A thermal protection adjustment range sets the motor full-load current window this starter can protect. For a 0.25 kW motor at 400 V, the full-load current typically falls around 0.7–0.8 A, which sits comfortably within this band. The 380/400 V AC coil means the control circuit must supply that voltage — do not assume a 230 V control transformer will pick it up. IP55 and IK07 make this enclosure suitable for washdown areas or outdoor installation under cover, but not for sustained high-pressure spray (IP65+) or heavy impact zones. The polycarbonate material is UV-stable for outdoor use but should not be exposed to solvents or aggressive chemicals. The four cable entries (two Pg 13, two Pg 16 at top and bottom) give flexibility for top-entry power and bottom-entry control wiring in a typical panel gland plate.

Frequently asked questions

How do I get current pricing and availability for LG1K065Q705?

Pricing and availability are confirmed at quote time against an RFQ. Because this part is obsolete, it is sourced through independent distribution — submit an RFQ for a current market quote and lead-time estimate.

What is the closest alternative to LG1K065Q705?

There is no official manufacturer successor. The closest functional equivalent would be a current-production TeSys LG or TeSys GV enclosed DOL starter with the same thermal adjustment range (0.63–1 A) and 380/400 V AC coil. Check the enclosure dimensions and cable entry layout against your existing cutout before specifying.

What compliance documentation does Schneider provide for LG1K065Q705?

The LG1K065Q705 is certified to IEC 60204-1 and IEC 60947-4-1 standards. It carries IP55 and IK07 ratings per IEC 60529. For RoHS, REACH, and UL documentation, consult the product certificate or contact Schneider Electric support with the full order code.

MPN
LG1K065Q705